Autonics SFC-R212-L technical specifications

Power supply24VDC
Allowable voltage range85 to 110% of rated voltage
Power consumption4.0W
InputON: ≥11 VDC ≥ 5mA, OFF: ≤ 5VDC ≤ 1mA
Input time≥ 50ms, feedback start (manual) : ≥ 100ms
Cable≤ 100m (≤ 100Ω, ≤ 10nF)
Safety outputRelay (A contact)
Instantaneous2 ×
Capacity240 VAC~ 5A, 30 VDC 5A
Life expectancyMechanical: ≥ 10,000,000 operations, Malfunction: ≥ 50,000 operations
Contact resistance≤ 100mΩ
Inductive load switchingIEC60947-5-1: AC-15 (230 V/2 A), DC-13 (24 V/1.5 A), UL508: B300/R300
Conditional short circuit current100A
Sub output1 × PNP transistor: X1
Load currentMax. 100mA
Leakage current0.1mA
International standardsIEC/EN 61508 (SIL3), IEC/EN 62061 (SILCL3) IEC/EN 60947-5-1, EN ISO 13849-1 (Category 4, PLe) UL listed E249635
WeightApprox. 80g (approx. 130g)
Specifications as listed by IndMALL. Confirm against the manufacturer's datasheet before ordering.

Overview

Autonics SFC-R212-L is a Safety Relay Units with 24VDC power supply and relay (A contact) safety output for machinery safety systems. This Autonics Safety Relay Units model supports 85–110% allowable voltage range , 4.0W power consumption , ≤100m cable length, manual feedback start ≥100ms, and max 100mA load current. In conveyors, packaging equipment, automated assembly stations, and machine guarding systems, SFC-R212-L Autonics Safety Relay Units manage emergency stop circuits and safety interlocks. Defined input thresholds and ≥50ms response timing support stable signal processing. The relay safety output enables direct switching of safety loads, while the PNP transistor sub output assists in status monitoring and fault indication.

Datasheet

Autonics datasheetsfc-sfc-r-series.pdf

Other models in this series

Compare SFC-R212-L with similar models in the same series. See all 7 models on the SFC Series page.

SFC-R212-L compared with other models in the series
ModelSafety outputSub outputPower consumptionInstantaneous
SFC-R212-L (this model)Relay (A contact)1 × PNP transistor: X14.0W2 ×
SFC-N322-23P channel FET2 × PNP transistor: X1, X2 (error)3.5W3 ×
SFC-R212Relay (A contact)1 × PNP transistor: X14.0W2 ×
SFC-R412-LRelay (A contact)1 × PNP transistor: X14.0W4 ×
SFC-R412Relay (A contact)1 × PNP transistor: X14.0W4 ×
SFC-422P channel FET2 × PNP transistor: X1, X2 (error)2.5W4 ×