EP4174-0002 - Beckhoff EtherCAT Box Analog Output

Image for reference. Refer to the datasheet for exact dimensions.

EP4174-0002 - Beckhoff EtherCAT Box Analog Output

The Beckhoff EP4174-0002 is an EtherCAT Box: number of channels 4 analog outputs, nominal voltage 24 V DC (-15%/+20%), resolution 16 bit.

Brand
Beckhoff
Model number
EP4174-0002

Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.

Beckhoff EP4174-0002 key specifications

TypeEtherCAT Box
ProtocolEtherCAT
Bus interface2 x M8 socket, 4-pin, a-coded, shielded
Number of channels4 analog outputs
Output connectionsM12 x 1, 5-pin, a-coded
Signal type-10/0…+10 V | -20/0/4…+20 mA, parameterizable per channel
Nominal voltage24 V DC (-15%/+20%)
Load> 5 kΩ | < 500 Ω
Resolution16 bit
Conversion time~ 40 µs
Measurement error/uncertainty< 0.1% (relative to full scale value)
Output error< 0.1% (relative to end value)
Actuator supplyfrom the auxiliary voltage UP
Power supply connectionfeed: 1 x M8 male socket, 4-pin, a-coded; downstream connection: 1 x M8 female socket, 4-pin, a-coded
Electrical isolation500 V
Current consumption from US120 mA
Weightapprox. 165 g
Operating temperature-25…+60°C
Source: Beckhoff product data, checked 27 Nov 2026.

Beckhoff EP4174-0002: frequently asked questions

How many channels does the EP4174-0002 have?

Number of channels: 4 analog outputs; Nominal voltage: 24 V DC (-15%/+20%).

Which bus connection does the EP4174-0002 use?

Bus interface: 2 x M8 socket, 4-pin, a-coded, shielded; Protocol: EtherCAT.

What resolution does the EP4174-0002 have?

Resolution: 16 bit; Conversion time: ~ 40 µs; Measurement error/uncertainty: < 0.1% (relative to full scale value).

Is the EP4174-0002 electrically isolated?

Electrical isolation: 500 V.