Image for reference. Refer to the datasheet for exact dimensions.
Delta DRL-24V120W1EN 24V 5A DIN Rail Power Supply
Delta 5A 24V DIN Rail Power Supply DRL-24V120W1EN delivers 120W stable DC output for industrial automation, control panels, and PLC systems.
- Brand
- Delta
- Model number
- DRL-24V120W1EN
- Series
- Delta SMPS LYTE II
- Product type
- SMPS
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Delta DRL-24V120W1EN technical specifications
| Output Current | 5A |
|---|---|
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 21.6-26.4Vdc |
| Output Power | 120W |
| Output Voltage Range | 21.6-26.4Vdc |
| Line Regulation | ± 0.5% @ 115Vac & 230Vac |
| Load Regulation | ± 0.5% |
| PARD | < 150mp @ 0°C to +7Vp0°C < 450mVpp @ -30°C to 0°C |
| Start-up Time | 500ms typ. @ 115Vac & 230Vac |
| Hold-up Time | 10ms typ. @ 115Vac (100% load) 16ms typ. @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 115Vac & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz) |
| Start-up with Capacitive Loads | 8,000µF Max |
| Rise Time | 30ms typ. @ 115Vac & 230Vac |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Input Current | 2.1A typ. @ 115Vac, 1.3A typ. @ 230Vac |
| Efficiency at 100% load | 88.5% typ.@ 230Vac |
| Inrush Current | 35A typ. @ 230Vac |
| Leakage Current | < 0.5mA @ 240Vac |
| Case Chassis / Cover | Aluminum / SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Input Terminal | 3 Pins (Rated 300V/30A) |
| Output Terminal | 4 Pins (Rated 300V/20A) |
| Noise Sound Pressure Level (SPL) | < 25dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Unit Weight | 0.45 kg (0.99 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6 m/s² (2G peak); 10 min per cycle, 60 min for X direction |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis |
| Operating Temperature | -30°C to +70°C (-40°C Cold Start) |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | > 40°C de-rate power by 1.67 % / °C @115Vac > 50°C de-rate power by 2.5 % / °C @230Vac |
| Operating Humidity | 20 to 90% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Pollution Degree | 2 |
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) |
Overview
Delta DRL-24V120W1EN is a 5A 24V DIN Rail Power Supply designed for industrial automation, control panels, and PLC systems that require consistent DC voltage. Supporting a nominal input voltage of 100–240Vac and a broad range of 90–264Vac, it ensures reliable operation in diverse industrial environments. Equipped with secure 3-pin and 4-pin input/output terminals and a Green LED (DC OK) indicator, this unit allows fast, reliable wiring and immediate operational status verification. Its DIN rail form factor facilitates tidy and space-efficient installation in control cabinets, while robust construction supports harsh operating conditions from -30°C to +70°C, including cold start at -40°C, and storage from -40°C to +85°C.
Datasheet
Delta datasheetdelta-drl-24v120w1en.pdfOther models in this series
Compare DRL-24V120W1EN with similar models in the same series. See all 18 models on the Delta SMPS LYTE II page.
| Model | Input Voltage Range | Output Voltage Adjustment Range | Output Voltage Range | Input Terminal |
|---|---|---|---|---|
| DRL-24V120W1EN (this model) | 90-264Vac | 21.6-26.4Vdc | 21.6-26.4Vdc | 3 Pins (Rated 300V/30A) |
| DRL-12V240W1EN | 90-264Vac | 10.8-13.2Vdc | 10.8-13.2Vdc | 3 Pins (Rated 300V/30A) |
| DRL-12V240W1ENA | 90-264Vac | 10.8-13.2Vdc | 10.8-13.2Vdc | 3 Pins (Rated 300V/30A) |
| DRL-15V240W1EN | 90-264Vac | 13.5-16.5 Vdc | 13.5-16.5Vdc | 3 Pins (Rated 300V/30A) |
| DRL-15V240W1ENA | 90-264Vac | 13.5-16.5 Vdc | 13.5-16.5Vdc | 3 Pins (Rated 300V/30A) |
| DRL-24V120W1ENA | 90-264Vac | 21.6-26.4Vdc | 21.6-26.4Vdc | 3 Pins (Rated 300V/30A) |
| DRL-24V240W1EN | 90-264Vac | 21.6-26.4Vdc | 21.6-26.4Vdc | 3 Pins (Rated 300V/30A) |
| DRL-24V240W1ENA | 90-264Vac | 21.6-26.4Vdc | 21.6-26.4Vdc | 3 Pins (Rated 300V/30A) |
| DRL-24V480W1EN | 90-264 Vac | 24-28 Vdc | 24-28 Vdc | 3 Pins (Rated 600 V / 30 A) |