Image for reference. Refer to the datasheet for exact dimensions.
Delta DVP04AD-E2 Programmable Logic Controller
Delta DVP04AD-E2 Programmable Logic Controller (PLC) offers 4-point Analog input with 10V/5V voltage and 20 mA, 0–20 mA, 4–20 mA current ranges.
- Brand
- Delta
- Model number
- DVP04AD-E2
- Series
- DVP-ES2/EX2 Series
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Delta DVP04AD-E2 technical specifications
| Power Supply Voltage | 24VDC (-15%~20%) |
|---|---|
| Resolution | 14-bit (-32,000 ~+32,000) |
| Analog I/O Modules | 4 points of Analog |
| Fuse capacity | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC |
| Power Consumption | 30VA |
| Voltage input/output | (10V, 5V) |
| Current input/output | (20 mA, 0~20 mA, 4~20 mA) |
| Spike Voltage Durability | 1500VAC (Primary-secondary); 1500VAC (Primary-PE); 500VAC (Secondary-PE) |
| Insulation Impedance | >5 MΩ (all I/O point-to-ground: 500VDC) |
| Noise Immunity | ESD: 8 kV Air Discharge EFT: Power Line, 2 kV Digital I/O: 1 kV Analog & Communication I/O: 1 kV RS: 26 MHz~1GHz, 10V/m |
| Earth | The diameter of grounding wire shall not be shorter than that of the power supply cable. (When many PLCs are in use at the same time, please make sure every PLC is properly grounded.) |
| Storagr Operation Temperature | Storage: -25ºC ~70ºC (temperature) Operation: 0ºC ~55ºC (temperature) |
| Storage Operation Humidity | Storage: -25ºC ~70ºC (temperature) Operation: 0ºC ~55ºC (temperature) |
| Response Time | 3 ms/ all channels |
| Input Signal Voltage | 24VDC ±10% (5 mA) |
Overview
Delta DVP04AD-E2 Programmable Logic Controller (PLC) is a reliable Analog I/O Module designed for precise signal acquisition with 4 Analog input points supporting 10V and 5V voltage signals and 20 mA, 0–20 mA, 4–20 mA current inputs . Manufactured by Delta , part of the Delta Programmable Logic Controller family, within the Delta DVP-ES2/EX2 Series . By adding accurate Analog signal processing to control systems, the Delta DVP04AD-E2 supports engineers in building efficient, reliable, and flexible automation setups that meet demanding industrial requirements. Protection is ensured through fuse capacity of ES: 2A/ 250VAC and SV: 2.5A/ 30VDC, along with spike voltage durability of 1500VAC (Primary-secondary), 1500VAC (Primary-PE), and 500VAC (Secondary-PE).
Datasheet
Delta datasheetdvp-series.pdfOther models in this series
Compare DVP04AD-E2 with similar models in the same series. See all 205 models on the DVP-ES2/EX2 Series page.
| Model | Number of Outputs and Type | Fuse Capacity | Power consumption | Program capacity |
|---|---|---|---|---|
| DVP04AD-E2 (this model) | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 30VA | — |
| DVP20EX200R | Analog (2), Relay (6) | 2A/ 250VAC | 30VA | 16k Steps |
| DVP20EX200T | 04/02 AI/AO | 2A/ 250VAC; SV: 2.5A/ 30VDC | — | 8k Steps |
| DVP30EX200R | 10 – Relay, Analog (1) | 2A/ 250VAC | — | — |
| DVP32XP200R | 16 – Relay | 2A/ 250VAC | — | 16k steps |
| DVP04DA-E2 | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 30VA | — |
| DVP02DA-E2 | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 1.5W | — |
| DVP06XA-E2 | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2.5W | — |
| DVP04TC-E2 | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 1.2W | — |