Image for reference. Refer to the datasheet for exact dimensions.
Delta DVP06XA-S PLC Analog Input Output Module
Delta DVP06XA-S modular PLC Analog Input / Output Module with 4 Analog inputs, 2 Analog outputs, 12-bit resolution, and RS-485 support.
- Brand
- Delta
- Model number
- DVP06XA-S
- Series
- DVP-S Series
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Delta DVP06XA-S technical specifications
| Built-in | RS-485 interface |
|---|---|
| Power Supply Voltage | 24VDC (-15%~20%) |
| Resolution | 12-bit |
| Analog I/O Modules | 4 points of Analog/ 2 points of Analog |
| Fuse capacity | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC |
| Power Consumption | 2W |
| Voltage input/output | input voltage (-10 V ~ +10 V)/ output voltage (0 V ~ +10 V) |
| Current input/output | current (-20 mA ~ +20 mA)/ current (0 mA ~ +20 mA) input |
| Spike Voltage Durability | 1500VAC (Primary-secondary); 1500VAC (Primary-PE); 500VAC (Secondary-PE) |
| Insulation Impedance | >5 MΩ (all I/O point-to-ground: 500VDC) |
| Noise Immunity | ESD: 8 kV Air Discharge EFT: Power Line, 2 kV Digital I/O: 1 kV Analog & Communication I/O: 1 kV RS: 26 MHz~1GHz, 10V/m |
| Earth | The diameter of grounding wire shall not be shorter than that of the power supply cable. (When many PLCs are in use at the same time, please make sure every PLC is properly grounded.) |
| Storagr Operation Temperature | Storage: -25ºC ~70ºC (temperature) Operation: 0ºC ~55ºC (temperature) |
| Storage Operation Humidity | Storage: -25ºC ~70ºC (temperature) Operation: 0ºC ~55ºC (temperature) |
| Response Time | 10ms |
| Input Signal Voltage | 24VDC ±10% (5 mA) |
Overview
Delta DVP06XA-S Programmable Logic Controller is a modular analog input and output module designed for accurate signal handling in industrial automation systems. It provides 4 analog input channels supporting voltage and current signals, along with 2 analog output channels for controlled signal transmission. Operating on a 24 VDC supply, the module integrates efficiently within DVP series architectures while supporting stable system expansion and reliable automation performance. Common implementations include temperature control, speed regulation, pressure sensing, and flow measurement where consistent analog conversion is essential for process stability. This connection between module structure, analog capability, and system integration makes the DVP06XA-S suitable for applications requiring accurate control and dependable analog performance.
Datasheet
Delta datasheetdvp-series.pdfOther models in this series
Compare DVP06XA-S with similar models in the same series. See all 205 models on the DVP-S Series page.
| Model | Number of Outputs and Type | Fuse Capacity | Power consumption | Program capacity |
|---|---|---|---|---|
| DVP06XA-S (this model) | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2W | — |
| DVP16SN11T | 16 – Transistor | 2A/ 250VAC; SV: 2.5A/ 30VDC | 4W | — |
| DVP16SP11T | 16 – Transistor | 2A/ 250VAC; SV: 2.5A/ 30VDC | 4W | — |
| DVP201LC-SL | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 5 W | — |
| DVP211LC-SL | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 5 W | — |
| DVP04AD-S2 | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2W | — |
| DVP04DA-S2 | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 4W | — |
| DVP06XA-S2 | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 4W | — |