Image for reference. Refer to the datasheet for exact dimensions.
Delta VFD002E21T Variable Frequency Drive
Delta VFD002E21T Variable Frequency Drive supports 0.2 kW, 0.25 HP motors with 230V, Single-phase, 200-240V, 50/60Hz input, Natural cooling.
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Delta VFD002E21T technical specifications
| Input Voltage / Frequency | 230V, Single-phase, 200-240V, 50/60Hz |
|---|---|
| Applicable Motor Output ( kW) | 0.2 kW |
| Applicable Motor Output (HP) | 0.25 HP |
| Output Capacity (kVA) | 0.6 kVA |
| Output Current (A) | 1.6 A |
| Cooling Method | Natural cooling |
| IP Level | IP20 |
| Pollution Degree | 2 |
| Storage/Transportation Temperature | -20ºC to 60ºC |
| Ambient Humidity | Below 90% RH (non-condensing) |
| V/F Pattern | Adjustable V/F pattern |
| Version Type | T: Frame A, built-in brake chopper |
| Input Frequency Tolerance | ±5% (47-63Hz) |
| Voltage Tolerance | ±10% (180-264V) |
| Net Weight (kg) | 1.1 kg |
Overview
Delta VFD002E21T Variable Frequency Drive is developed for compact automation systems requiring controlled motor speed with integrated braking functionality. This Delta 1.6A 230V Single-Phase with Brake Chopper drive supports 0.2 kW motor applications using a single-phase 200–240 VAC input supply and delivers 1.6 A rated output current for stable low-power machine operation. Applications involving positioning systems, compact conveyors, small automation equipment, and light-duty handling machines benefit from smoother speed control and dependable braking response during operation. Compact automation panels frequently integrate the VFD002E21T to improve motor management while reducing electrical stress caused by direct startup and stopping conditions.
Datasheet
Delta datasheete-series.pdfOther models in this series
Compare VFD002E21T with similar models in the same series. See all 79 models on the E Series page.
| Model | Cooling Method | Applicable Motor Output ( kW) | Applicable Motor Output (HP) | Output Capacity (kVA) |
|---|---|---|---|---|
| VFD002E21T (this model) | Natural cooling | 0.2 kW | 0.25 HP | 0.6 kVA |
| VFD002E11C | Natural cooling | 0.2 kW | 0.25 HP | 0.6 kVA |
| VFD002E11T | Natural cooling | 0.2 kW | 0.25 HP | 0.6 kVA |
| VFD002E21A | Natural cooling | 0.2 kW | 0.25 HP | 0.6 kVA |
| VFD002E21C | Natural cooling | 0.2 kW | 0.25 HP | 0.6 kVA |
| VFD002E23A | Natural cooling | 0.2 kW | 0.25 HP | 0.6 kVA |
| VFD002E23C | Natural cooling | 0.2 kW | 0.25 HP | 0.6 kVA |
| VFD004E11C | Natural cooling | 0.4 kW | 0.5 HP | 1 kVA |
| VFD004E11T | Natural cooling | 0.4 kW | 0.5 HP | 1 kVA |