Image for reference. Refer to the datasheet for exact dimensions.
Delta VFD4500C63B-21 Variable Frequency Drive
Delta VFD4500C63B-21 Variable Frequency Drive supports 355 kW, 475 HP motors with 3-Phase 525VAC ~ 690VAC, 50 / 60Hz input, Fan Cooling.
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Delta VFD4500C63B-21 technical specifications
| Input Voltage / Frequency | 3-Phase 525VAC ~ 690VAC ( -15% ~ +10%), 50 / 60Hz |
|---|---|
| Output Capacity (kVA) Normal Duty | 442.7 kVA |
| Output Current (A) Normal Duty | 385 A |
| Applicable Motor Output (kW) Normal Duty | 355 kW |
| Applicable Motor Output (HP) Normal Duty | 475 HP |
| Cooling Method | Fan Cooling |
| Efficiency (%) | 98 |
| IP Level | IP20 |
| NEMA Protection Level | NEMA 1 |
| Storage/Transportation Temperature | -25 ~ 70 |
| Braking Chopper | Optional Braking Chopper |
| Control Method | Pulse Width Modulated (PWM) |
| Installation Type | Wall mount with 690V rated current |
| V/F Curve | 4-point adjustable V/F curve and square curve |
| Input Frequency Tolerance | 47 ~ 63Hz |
| Voltage Tolerance | 446 ~ 759VAC |
| Drive Weight (Kg) | 243±5 kg |
Overview
Delta VFD4500C63B-21 Variable Frequency Drive is designed for industrial automation systems requiring dependable motor speed regulation with stable high-performance operational capability. This Delta 4500kW High-Performance Solution supports 475 HP motor applications using a three-phase 525V–690V AC input supply and delivers 385 A rated output current for controlled machine operation. The drive uses fan cooling with an IP20 enclosure suitable for cabinet-integrated industrial environments requiring internal protection. Applications involving conveyors, compressors, pumps, ventilation systems, and heavy-duty process machinery benefit from smooth acceleration and controlled operational performance during continuous industrial operation. Its fan cooling structure and cabinet-friendly IP20 enclosure make it suitable for organized industrial control panel installations.
Datasheet
Delta datasheetc2000-series.pdfOther models in this series
Compare VFD4500C63B-21 with similar models in the same series. See all 117 models on the C2000 Series page.
| Model | Cooling Method | Applicable Motor Output (HP) Normal Duty | Applicable Motor Output (kW) Normal Duty | Output Capacity (kVA) Normal Duty |
|---|---|---|---|---|
| VFD4500C63B-21 (this model) | Fan Cooling | 475 HP | 355 kW | 442.7 kVA |
| VFD4500C63B-00 | Fan Cooling | 475 HP | 355 kW | 442.7 kVA |
| VFD5600C63B-00 | Fan Cooling | 600 HP | 450 kW | 534.7 kVA |
| VFD6300C63B-00 | Fan Cooling | 850 HP | 630 kW | 776 kVA |
| VFD4000C63B-21 | Fan Cooling | 425 HP | 315 kW | 402.5 kVA |
| VFD5600C63B-21 | Fan Cooling | 600 HP | 450 kW | 534.7 kVA |
| VFD6300C63B-21 | Fan Cooling | 850 HP | 630 kW | 776 kVA |
| VFD055C43A | Fan Cooling | — | — | — |
| VFD037C43A | Fan Cooling | — | — | — |