Delta VFD5A5MS43ENSAA Variable Frequency Drive
Delta VFD5A5MS43ENSAA Delta 460V 3-phase 2.2kW Drive with MS300 series motor control and IP40 design.
- Brand
- Delta
- Model number
- VFD5A5MS43ENSAA
- Series
- MS300 Series
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Delta VFD5A5MS43ENSAA technical specifications
| Input Voltage / Frequency | 460V, Three-phase AC 380 V ~480 V, 50 / 60 Hz |
|---|---|
| Applicable Motor Output ( kW) | 2.2 kW |
| Applicable Motor Output (HP) | 3 HP |
| Heavy Duty Rated Output Current (A) | 5.5 A |
| Normal Duty Rated Output Current (A) | 6.5 A |
| Cooling Method | Natural air cooling |
| IP Level | IP40 (Anti-dust) |
| EMC Filter | None EMC Filter |
| Safe Torque Off (STO) | Integrated STO |
| Model Type | Standard Model |
| Braking Chopper | Built-in Braking Chopper |
| Output Frequency | 0.00 ~ 599.00 Hz (±0.1%) |
| Control Methods | V/F, SVC, FOC Sensorless |
| Size: W × H (mm) | 87×157 |
| Size: D (mm) | 152 |
Overview
Delta VFD5A5MS43ENSAA Variable Frequency Drive is a Delta 460V 3-phase 2.2kW Drive designed for controlled motor operation in industrial automation systems. It supports 2.2 kW and 3 HP applications with a stable 460V three-phase AC input range of 380V~480V at 50/60 Hz. This model delivers 5.5 A heavy duty output current and 6.5 A normal duty output current , supporting stable motor performance across varying industrial load conditions. The Delta VFD5A5MS43ENSAA is commonly integrated into industrial automation systems including conveyors, compressors, pumps, packaging machinery, and process equipment requiring dependable three-phase motor speed regulation. Its compact structure supports organized installation inside industrial electrical control panels.
Datasheet
Delta datasheetms300-series.pdfOther models in this series
Compare VFD5A5MS43ENSAA with similar models in the same series. See all 145 models on the MS300 Series page.
| Model | Cooling Method | Applicable Motor Output ( kW) | Applicable Motor Output (HP) | Heavy Duty Rated Output Current (A) |
|---|---|---|---|---|
| VFD5A5MS43ENSAA (this model) | Natural air cooling | 2.2 kW | 3 HP | 5.5 A |
| VFD7A5MS21ENSAA | Natural air cooling | 1.5 kW | 2 HP | 7.5 A |
| VFD11AMS21ENSAA | Fan cooling | 2.2 kW | 3 HP | 11 A |
| VFD11AMS23ENSAA | Fan cooling | 2.2 kW | 3 HP | 11 A |
| VFD17AMS23ENSAA | Fan cooling | 3.7 kW | 5 HP | 17 A |
| VFD9A0MS43ENSAA | Fan cooling | 3.7 kW | 5 HP | 9 A |
| VFD6A6MS53ANSAA | Fan cooling | 3.7 kW | 5 HP | 6.6 A |
| VFD7A5MS21ANSHA | Natural air cooling | 1.5 kW | 2 HP | 7.5 A |
| VFD11AMS21ANSHA | Fan cooling | 2.2 kW | 3 HP | 11 A |