Image for reference. Refer to the datasheet for exact dimensions.
Leuze HT49C.UC/M4 Photoelectric Sensor
IndMALL Offers Leuze Interference blanking, Transient protection diffuse sensor HT49C.UC/M4-50127432 at Discounted Rates. specs 0.005 ... 3 m.
- Brand
- Leuze
- Model number
- HT49C.UC/M4
- Series
- Leuze Photoelectric Sensor
- Product type
- Photoelectric Sensor
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Leuze HT49C.UC/M4 technical specifications
| Design | Cubic |
|---|---|
| Operating principle | Diffuse reflection principle with background suppression |
| Special version | - |
| Sensing Distance | 0.005 ... 3 m |
| Beam path | - |
| Light source | LED, Red |
| Wavelength | 630 nm |
| Type of light spot geometry | - |
| Supply voltage UB | 20 ... 250 V, AC/DC |
| Switching Output 1 | MOSFET semiconductor, NO (normally open) |
| Switching principle | Light/dark switchable |
| Switching Output 2 | - |
| Switching principle | - |
| Switching frequency | 150 Hz |
| Response time | 3.3 ms |
| Function | Signal OUT Voltage supply |
| Type of connection | Cable |
| Cable length | 2,000 mm |
| Sheathing material | PVC |
| Cable color | Black |
| Number of conductors | 5 -wire |
| Wire cross section | 0.34 mm² |
| Dimension (W x H x L) | 31 mm x 104 mm x 55.5 mm |
| Housing material | Plastic |
| Lens cover material | Plastic |
| Housing color | Red |
| Type of display | LED |
| Ambient temperature, operation | -40 ... 60 °C |
| Ambient temperature, storage | -40 ... 70 °C |
| Degree of protection | IP 67 |
Overview
HT49C.UC/M4 is a Photoelectric Sensor with 0.005–3 m sensing distance , 630 nm red LED , MOSFET NO output. The Leuze HT49C.UC/M4 is a Leuze Interference blanking, Transient protection diffuse sensor in the Leuze Photoelectric Sensor category and HT series, operating on the diffuse reflection principle with background suppression , 20–250 V AC/DC supply , 150 Hz switching frequency, 3.3 ms response time, 2,000 mm PVC cable with 5-wire 0.34 mm² cross section, and IP67 protection. The AC/DC supply range allows integration into varied control panels.
Datasheet
Leuze datasheetleuze-ht49c-uc-m4-50127432.pdfCompare with similar models
Compare HT49C.UC/M4 with similar Leuze models. See all 1384 models on the Leuze Photoelectric Sensor page.
| Model | Sensing Method | Sensing Distance | Output | Connection | Housing |
|---|---|---|---|---|---|
| HT49C.UC/M4 (this model) | Background suppression | 0.005 ... 3 m | Light/Dark ON | Cable, 2 m | Rectangular |
| HT46CL2/4P-200-M12 | Background suppression | 0.05 ... 1 m | PNP, Light ON | Cable + connector, 4-pin | Rectangular |
| HT46CL2/4P-M12 | Background suppression | 0.05 ... 1 m | PNP, Light ON | Connector, 4-pin | Rectangular |
| HT46CL2/6G-M12 | Background suppression | 0.05 ... 1 m | Push-pull, Light/Dark ON | Connector, 4-pin | Rectangular |
| HT46CL2/48-M12 | Background suppression | 0.05 ... 1 m | PNP, Light ON | Connector, 4-pin | Rectangular |
| HT49C.UC/M4-TB | Background suppression | 0.005 ... 3 m | Light/Dark ON | Terminals | Rectangular |
| HT49C.UC/TS | Background suppression | 0.005 ... 3 m | Relay, Light/Dark ON | Cable, 2 m | Rectangular |
| HT49C.UC/TS-TB | Background suppression | 0.005 ... 3 m | Relay, Light/Dark ON | Terminals | Rectangular |
| HT49C.UCH/TS-TB | Background suppression | 0.005 ... 3 m | Relay, Light/Dark ON | Terminals | Rectangular |