Image for reference. Refer to the datasheet for exact dimensions.
Multispan AVF-29T-E3-06: Digital AVF Meters
AVF-29T-E3-06 Multispan Digital AVF Meters. IndMALL offers quick solutions—contact us for details!
- Brand
- Multispan
- Model number
- AVF-29T-E3-06
- Series
- Multispan Digital AVF Meter
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Multispan AVF-29T-E3-06 technical specifications
| Direct Voltage AC | 30 to 300V (L - N); 50 to 520V (L - L) |
|---|---|
| Burden (Voltage) | < 0.2 VA |
| Primary PT Ratio | 100V to 520KV Selectable |
| Primary CT Ratio | 9999A Selectable |
| Secondary Current AC | 5A or 1A |
| Secondary PT Ratio | 100V to 520V Selectable |
| Burden (Current) | < 0.2 VA |
| Overload | Upto 6A Continuous |
| Frequency | 45.0 to 65.0 Hz |
| Voltage | VLL, VLN, Avg. |
| Current | CT Input: 30A with DIN 30AX CT |
| Frequency (Calculated) | System Frequency |
| Load Hour | Upto 9999 Hr 59 min |
| Accuracy | Class 0.5 (Standard) |
| Power Supply | 100 to 270V AC, 50/60Hz |
| Burden (Power) | 4VA |
| Display | 3-Digit, 3-Line, 7-Segment, 0.59” RED LED |
| Key | Set/Ent, Inc, Dec/Scroll |
| LED Indication | A, KA, KV, VLL, VLN, Avg, HZ, L1, L2, L3, PS |
| Working Temperature | 0 to 55°C |
| Storage Temperature | 0 to 55°C |
| Relative Humidity | 95% RH Non-Condensing |
| Protection Level | IP-65 (Front side As per IS/IEC 60529 : 2001) |
| Size (mm) | 72 (H) x 72 (W) x 45 (D) |
| Panel Cutout (mm) | 68 (H) x 68 (W) |
Overview
Technical Specifications of Multispan Digital AVF Meters AVF-29T-E3-06:
Other models in this series
Compare AVF-29T-E3-06 with similar models in the same series. See all 12 models on the Multispan Digital AVF Meter page.
| Model | Direct Voltage AC | Power Supply | Voltage | Burden (Power) |
|---|---|---|---|---|
| AVF-29T-E3-06 (this model) | 30 to 300V (L - N); 50 to 520V (L - L) | 100 to 270V AC, 50/60Hz | VLL, VLN, Avg. | 4VA |
| AVF-19D-B1-N3 | 30 to 300V (L - N); 50 to 520V (L - L) | 230V AC, 50Hz ± 20% | VLL, VLN, Avg | 3VA |
| AVF-19D-B1-N6 | 30 to 300V (L - N); 50 to 520V (L - L) | 230V AC, 50Hz ± 20% | VLL, VLN, Avg | 3VA |
| AVF-19D-B1-N8 | 30 to 300V (L - N); 50 to 520V (L - L) | 230V AC, 50Hz ± 20% | VLL, VLN, Avg | 3VA |
| AVF-29T-E3-00 | 30 to 300V (L - N); 50 to 520V (L - L) | 100 to 270V AC, 50/60Hz | VLL, VLN, Avg. | 4VA |
| AVF-29T-E3-07 | 30 to 300V (L - N); 50 to 520V (L - L) | 100 to 270V AC, 50/60Hz | VLL, VLN, Avg. | 4VA |
| AVF-29T-E3-08 | 30 to 300V (L - N); 50 to 520V (L - L) | 100 to 270V AC, 50/60Hz | VLL, VLN, Avg. | 4VA |
| AVF-19T-E3-N0 | 30 to 300V (L - N) 50 to 520V (L - L) | 100 to 270V AC/DC,50/60Hz | VLL, VLN, Avg. | 4VA |
| PM-133-E3-00 | 50 to 300V (L - N)87 to 519V (L - L) | 100 to 270V AC/DC, 50/60Hz | VLL, VLN, Avg | 4VA |