Image for reference. Refer to the datasheet for exact dimensions.
Omron G3TA-ODX02S-US DC12 Solid-state Relay
Omron G3TA-ODX02S-US DC12 Solid-state Relay (SSR) offers 24 VDC input, 5 to 48 VDC output, Single-phase, 2-element, Photocoupler isolation.
- Brand
- Omron
- Model number
- G3TA-ODX02S-US DC12
- Series
- G3TA Series
- Product type
- Solid State Relay
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Omron G3TA-ODX02S-US DC12 technical specifications
| Number Of Phases | Single-phase |
|---|---|
| Isolation Method | Photocoupler |
| Mounting | socket |
| Operating Indicator | Equipped |
| Terminal Structure | Plug-in terminal |
| Product Classification | Relay compatible |
| Number Of Elements | 2 |
| Zero Cross Function | Equipped |
| Input Rated Voltage | 24 VDC |
| Input Current | 6.5 kΩ±20% |
| Input Operate Voltage | 19.2 V max.DC |
| Input Release Voltage | 2 V min.DC |
| Output Rated Load Voltage | 5 to 48 VDC |
| Output Load Voltage Range | 4 to 60 VDC |
| Output Minimum Load Current | 100 µA to 3 A |
| Output Load Current | 0.01 to 2 A (at 60 ℃) |
| Output Inrush Current Resistivity | 12 A (60 Hz 1 cycle) |
| Operate Time | 0.5 ms max. |
| Release Time | 2 ms max. |
| Output On Voltage Drop | Main circuit: 1.6 V max. (RMS) |
| Leakage Current | 5 µA max. |
| Insulation Resistance | 100 MΩ min. (at 500 VDC) |
| Dielectric Strength | 2000 VAC 50/60 Hz 1 min |
| Vibration Resistance | 10 to 55 to 10 Hz, 0.175 mm single amplitude (0.75 mm double amplitude) |
| Shock Resistance | 1000 m/s 2 (DIN Track mounting) |
| Ambient Temperature Operating | -30 to 80 ℃ (with no freezing or condensation) |
| Ambient Temperature Storage | -30 to 100 ℃ (with no freezing or condensation) |
| Ambient Humidity Operating | 45 to 85% RH |
| Weight | Approx. 16 g |
Overview
Omron G3TA-ODX02S-US DC12 is a single-phase, 2-element socket relay with photocoupler isolation and a plug-in terminal structure. Its output is rated from 5 to 48 VDC and operates across 4 to 60 VDC, with a listed load-current range of 0.01 to 2 A at 60°C. The relay includes an operating indicator and zero-cross function, with 0.5 ms max. operate time and 2 ms max. release time. Despite the DC12 model suffix, the supplied row lists a 24 VDC rated input and a 19.2 to 26.4 VDC operating range, so those values are presented exactly as provided. For the closely related DC24 model, see G3TA-ODX02S-US DC24 .
Datasheet
Omron datasheetg3ta-series.pdfOther models in this series
Compare G3TA-ODX02S-US DC12 with similar models in the same series. See all 4 models on the G3TA Series page.
| Model | Isolation Method | Output On Voltage Drop | Leakage Current | Mounting |
|---|---|---|---|---|
| G3TA-ODX02S-US DC12 (this model) | Photocoupler | Main circuit: 1.6 V max. (RMS) | 5 µA max. | socket |
| G3TA-IDZR02S-US DC5-24 | Photocoupler | Main circuit: 1.6 V max. (RMS) | 5 µA max. | socket |
| G3TA-OA202SZ-US DC24 | Phototriac | 1.6 V max. (RMS) | 5 mA max. (at 200 VAC) | Socket |
| G3TA-ODX02S-US DC24 | Photocoupler | 1.6 V max. | 1 mA max. | Socket |