Talk to our engineer for Omron Flicker OFF start timer H3DT-F AC/DC24-240 with special pricing. Specs 24 to 240VAC 50/60Hz, 24-240VDC, DPDT.

Brand
Omron
Model number
H3DT-F AC/DC24-240
Series
H3DT Series
Product type
Timers

Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.

Omron H3DT-F AC/DC24-240 technical specifications

Rated power supply voltage24 to 240 VAC 50/60 Hz 24 to 240 VDC Ripple 20% max.
Allowable voltage variable range85% to 110% of rated voltage
Reset voltage10% min. of rated voltage.
Number of time ranges8
Operation modeFlicker OFF start, Flicker ON start
Control output (Type)Relay output (SPDT)
Control output (Contact output)Resistive load: 250 VAC 5 A (cosφ=1)/5 A at 30 VDC/0.5 A max. at 125 VDC Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Connection methodPush-In Plus Terminal Block
Power consumptionApprox. 1.9 VA (at 240 VAC) Approx. 0.6 W (at 240 VDC)/Approx. 0.3 W (at 24 VDC)
Ambient temperature rangeOperating: -20 to 60 ℃ (with no icing) Storage: -40 to 70 ℃ (with no icing)
Accuracy of operating time±1% FS max. (±1% ±10 ms in a range of 1.2 s)
Setting error±10% FS ±0.05 s max.
Influence of voltage±0.5% FS max. (±0.5% ±10 ms in a range of 1.2 s)
Influence of temperature±2% FS max. (±2% ±10 ms in a range of 1.2 s)
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric strengthBetween charged metal part and operating section: 2,900 VAC 50/60 Hz for 1 min Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min
Impulse withstand voltageBetween power terminals: 5 kV Between conductor terminal and operating section: 7.4 kV
Noise immunity±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunityMulfunction: 4 kV, Destruction: 8 kV
Vibration resistanceDestruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
Shock resistanceDestruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions
Degree of protectionIP30 (Terminal Block: IP20)
Ambient temperature rangeOperating: -20 to 60 ℃ (with no icing) Storage: -40 to 70 ℃ (with no icing)
Ambient humidity rangeOperating: 25 to 85%
Life expectancy (relay output)Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
WeightApprox. 90 g
Specifications as listed by IndMALL. Confirm against the manufacturer's datasheet before ordering.

Overview

The Omron H3DT-F AC/DC24-240 Solid-state Timer is engineered for stable timing control with an allowable voltage variable range of 85% to 110% of rated voltage, ensuring consistent performance across applications. With 8 time ranges and a Relay output (SPDT) control output, it provides dependable timing flexibility. The Push-In Plus Terminal Block offers secure and efficient wiring. Manufactured by Omron , listed under Omron Timers , and part of the Omron H3DT Series .

Datasheet

Omron datasheeth3dt-datasheet.pdf

Other models in this series

Compare H3DT-F AC/DC24-240 with similar models in the same series. See all 12 models on the H3DT Series page.

H3DT-F AC/DC24-240 compared with other models in the series
ModelNumber of time ranges
H3DT-F AC/DC24-240 (this model)8
H3DT-A1 AC/DC24-2408
H3DT-A2 AC/DC24-2408
H3DT-G AC/DC24-2402
H3DT-HBL AC/DC24-482
H3DT-HBS AC/DC24-482
H3DT-HDL AC200-2402
H3DT-HDS AC200-2402
H3DT-L1 AC/DC24-2408