Omron H5CX-A11D-N technical specifications
| Rated supply voltage | 24 VAC (50/60 Hz) 12 to 24 VDC (Ripple 20% max.) |
|---|---|
| Operating voltage range | 85 to 110% of rated supply voltage |
| Connection method | 11-pin round socket |
| Mounting method | Flush mounting / Surface mounting |
| Power consumption | Approx. 5.1 VA/Approx. 2.4 W |
| Time ranges (Number of ranges) | 10 |
| Time ranges | 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1 to 9999 s 0.1 to 999.9 min 1 to 9999 min 0.1 to 999.9 h 1 to 9999 h 1 s to 99 min 59 s 1 min to 99 h 59 min |
| Input method | No-voltage (NPN)/Voltage (PNP) input (selectable) |
| Output modes | A: Signal ON delay (Ⅰ) A-1:Signal ON delay (Ⅱ) A-2: Power ON delay (Ⅰ) A-3: Power ON delay (Ⅱ) b: Repeat cycle (Ⅰ) b-1: Repeat cycle (Ⅱ) d: Signal OFF delay E: Interval F: Cumulative Z: ON/OFF-duty adjustable flicker S: Stopwatch toff: Flicker OFF start (Ⅰ) ton: Flicker ON start (Ⅰ) toff-1: Flicker OFF start (Ⅱ) ton-1: Flicker ON start (Ⅱ) |
| Reset system | Power reset (depending on output mode)/Automatic reset (depending on output mode)/External reset/Manual reset |
| Timer mode | Elapsed time (UP) and remaining time (DOWN) (selectable) |
| Display method | 7-segment negative transmissive LCD 4 digit |
| Character height | Present value: 12 mm (Red, green or orange programmable) Set value: 6 mm (green) |
| Ambient temperature range | -10 to 55 ℃ (with no freezing or condensation) When mount timer side by side: -10 to 50 ℃ (with no freezing or condensation) |
| Ambient humidity (Operating) | 25 to 85% |
| Accuracy of operating time | Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.) |
| Setting error | Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.) |
| Influence of voltage | Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.) |
| Influence of temperature | Power-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.) |
| Insulation resistance | Between current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) Between non-continuous contacts: 100 MΩ min. (at 500 VDC) |
| Dielectric strength | Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between operating power circuit and input circuit: 2000 VAC 50/60 Hz 1 min Between control output, and power supply/input circuit: 2000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min |
| Impulse withstand voltage | Between power terminals: 1.0 kV Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV |
| Noise immunity | Between power terminals: ±1.5 kV Between input terminals: ±600 kV square-wave noise by noise simulator, pulse width: 100 ns/1 µs, 1-ns rise |
| Static immunity | Mulfunction: 8 kV, Destruction: 15 kV |
| Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz 0.35 mm single amplitude each in 3 directions for 10 min |
| Shock resistance | Destruction: 300 m/s2, 3 times each in 3 axes each directions Malfunction: 100 m/s2, 3 times each in 6 directions |
| Life expectancy | Electrical: 100,000 operations min. (5 A at 250 VAC resistive load at 1800 operations/h, 23 ℃) Mechanical: 10 million operations min. (under no load at 1,800 operations/h, 23 ℃) |
| Degree of protection | IEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter) |
| Case color | Black (Munsell N1.5) |
| Accessory (sold separately) | Soft Cover: Y92A-48F1 Hard Cover: Y92A-48 Flush mounting adapter: Y92F-30/Y92F-45/Y92F-38 Waterproof packing: Y92S-29 Replacement Front Panel: Y92P-CXT4S/Y92P-CXT4G/Y92P-CXT4B |
| Ambient temperature range | -10 to 55 ℃ (with no freezing or condensation) When mount timer side by side: -10 to 50 ℃ (with no freezing or condensation) |
| No-voltage input (Solid state input) | Short-circuit (ON) impedance: 1 kΩ max. (Leakage current (0 Ω): Approx. 12 mA) Short-circuit (ON) residual voltage: 3 V max. Open circuit impedance: 100 kΩ min. (The DC voltage must be 30 VDC max.) |
| No-voltage input (Contact input) | Use contact which can adequately switch 5 mA at 10 V |
| No-voltage input (Applicable two-wire sensor) | Leakage current: 1.5 mA max. Switching capacities: 5 mA min. Residual voltage: 3.0 VDC max. Operating voltage: 10 VDC |
| Voltage input | High level: 4.5 to 30 VDC Low level: 0 to 2 VDC (Input resistance 4.7 kΩ) |
| Control output (Solid state output) | Time-limit contact: SPDT Resistive load: 5 A at 250 VAC/30 VDC (cosφ = 1) Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value) |
| Power reset | Minimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1 and toff-1 mode) |
| Key protect method | Key protect Switch |
| Memory backup method | EEP-ROM (number of writes: 100,000 operations min., Service life: 10 years min.) |
| Attachment | Label for DIP switch settings |
| Weight | Main Unit: Approx. 115 g |
Overview
The Omron H5CX-A11D-N Timer is a compact industrial timing unit designed to operate within 85 to 110% of rated supply voltage.It features 10 time ranges along with a No-voltage (NPN)/Voltage (PNP) input (selectable) input method. Manufactured by Omron , listed under Omron Timers , this model belongs to the Omron H5CX Series and supports Flush mounting / Surface mounting with 11-pin round socket connections in a Black (Munsell N1.5) case. IndMALL Dealing in Omron 48 mm x 48 mm x 69.7 mm Timer, H5CZ-L8E at the best rates. Unlock Exclusive Pricing with a Quote for your requirement of Omron 48 mm x 48 mm x 69.7 mm Timer.
Datasheet
Omron datasheeth5cx-datasheet.pdfOther models in this series
Compare H5CX-A11D-N with similar models in the same series. See all 15 models on the H5CX Series page.
| Model | Mounting method | Time ranges (Number of ranges) | Connection method | Power consumption |
|---|---|---|---|---|
| H5CX-A11D-N (this model) | Flush mounting / Surface mounting | 10 | 11-pin round socket | Approx. 5.1 VA/Approx. 2.4 W |
| H5CX-A-N | Flush mounting | 10 | Screw terminal | Approx. 6.2 VA |
| H5CX-A11-N | Flush mounting | 10 | 11-pin round socket | Approx. 6.2 VA |
| H5CX-A11S-N | Flush mounting / Surface mounting | 10 | 11-pin round socket | Approx. 6.2 VA |
| H5CX-A11SD-N | Flush mounting / Surface mounting | 10 | 11-pin round socket | Approx. 5.1 VA/Approx. 2.4 W |
| H5CX-AD-N | Flush mounting | 10 | Screw terminal | Approx. 5.1 VA/Approx. 2.4 W |
| H5CX-AS-N | Flush mounting | 10 | Screw terminal | Approx. 6.2 VA |
| H5CX-ASD-N | Flush mounting | 10 | Screw terminal | Approx. 5.1 VA/Approx. 2.4 W |
| H5CX-BWSD-N | Flush mounting | 4 | Screw terminal | Approx. 2.3 W |