IndMALL 2.0 preview — for review only, not indexed by search engines. Links reflect the live IndMALL site; WhatsApp buttons open the real IndMALL enquiry number.

Industrial automation products & suppliers across India

Omron H7CC-AUD Digital Counter

Image for reference. Refer to the datasheet for exact dimensions.

Omron H7CC-AUD Digital Counter

Omron H7CC-AUD Counter with relay + transistor outputs, 24 VAC/12–48 VDC, 10 kHz speed, and multi-function counting for advanced automation.

Brand
Omron
Model number
H7CC-AUD
Series
H7CC Series
Product type
Counters

Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.

Omron H7CC-AUD technical specifications

Power consumption5.5 VA/3.3 W
External power supply12 VDC (±10%), 100 mA (except for H7CC-A8@ models) Refer to Precautions for Correct Use on page 61 for details
Max. counting speed30 Hz (minimum pulse width: 16.7 ms) or 10 kHz (minimum pulse width: 0.05 ms) (selectable) (ON/OFF ratio 1:1) *Common setting for CP1 and CP2
Counter Input modeIncrement (UP), decrement (DOWN), increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs)), UP/DOWN D (command input), UP/DOWN E (individual inputs), UP/DOWN E (quadrature inputs)
Input signalCP1, CP2, reset 1, and reset 2
Prescaling functionYes (0.001 to 99.999)
Decimal point adjustmentRefer to the separate table for tachometer function ratings
ClassificationPreset counter/ Tachometer
Configuration• 1-stage preset counter • 2-stage preset counter • Total and preset counter • Batch counter • Dual counter • Twin counter • Tachometer
Power supply voltage"24 VAC/ 12 to 48 VDC"
Mounting methodFlush mounting
External connectionsScrew terminals
OutputsContact output (SPST+SPDT)
Digits6 digits -99999 to 999999 (-5 digits to +6 digits)
Operating voltage fluctuation range85% to 110% of rated supply voltage (12 to 48 VDC: 90% to 110%)
Auto-zero time/Startup time0.01 to 99.99 s
Sensor waiting timeExternal (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and automatic reset (internal according to C, R, P, and Q mode operation)
Control output• Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) • Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC max. (approx. 1 V), Leakage current: 0.1 mA max.
Display7-segment, negative transmissive LCD Character height Count value: 10 mm (white) Set value: 6 mm (green)
Memory backupNon-volatile memory (overwrites: 100,000 times min.) that can store data for 10 years min.
Storage temperature range-10 to 55°C (-10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation)
Operating humidity range25% to 85%
Input modeNo-voltage (NPN) input/voltage (PNP) input (switchable) No-voltage inputs: ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min. Voltage input: High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
Degree of protectionIEC IP66 for panel surface only and only when Y92S-P6 Waterproof Packing is used
Case colorBlack (N1.5)
Specifications as listed by IndMALL. Confirm against the manufacturer's datasheet before ordering.

Overview

The Omron H7CC-AUD Counter offers advanced preset and tachometer capabilities with a dual-output design combining SPST transistor and SPDT relay outputs for flexible load handling. Operating on 24 VAC or 12–48 VDC, it features screw-terminal wiring, selectable 30 Hz or 10 kHz speeds, and multiple UP/DOWN and quadrature modes. Dual reset inputs, a clear LCD, and non-volatile memory ensure accuracy and dependable operation. Supporting batch, dual, and twin counting, it suits complex automation tasks. Manufactured by Omron and listed under Omron Counter solutions, this model is part of the versatile Omron H7CC Series .

Datasheet

Omron datasheeth7cc-series.pdf

Other models in this series

Compare H7CC-AUD with similar models in the same series. See all 20 models on the H7CC Series page.

H7CC-AUD compared with other models in the series
ModelMounting methodExternal connectionsInput signalClassification
H7CC-AUD (this model)Flush mountingScrew terminalsCP1, CP2, reset 1, and reset 2Preset counter/ Tachometer
H7CC-ADFlush mountingScrew terminalsCP1, CP2, reset, and total resetPreset counter
H7CC-ASFlush mounting or surface mounting11-pin socketCP1, CP2, reset 1, and reset 2Preset counter
H7CC-ASDFlush mountingScrew terminalsCP1, CP2, reset, and total resetPreset counter
H7CC-AUFlush mountingScrew terminalsCP1, CP2, reset 1, and reset 2Preset counter/ Tachometer
H7CC-A11DFlush mounting or surface mounting11-pin socketCP1, CP2, reset, and total resetPreset counter
H7CC-AWDFlush mountingScrew terminalsCP1, CP2, reset 1, and reset 2Preset counter/ Tachometer
H7CC-AWSFlush mountingScrew terminalsCP1, CP2, reset 1, and reset 2Preset counter/ Tachometer
H7CC-AWSDFlush mountingScrew terminalsCP1, CP2, reset 1, and reset 2Preset counter/ Tachometer