Image for reference. Refer to the datasheet for exact dimensions.
Omron MY4N AC24 Relay
Omron MY4N AC24 Relay offers Plug-in terminal, Closed type (cover),4PDT contacts, Single contact method, Socket mounting, 250 VAC 125 VDC contact voltage.
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Omron MY4N AC24 technical specifications
| Terminal Structure | Plug-in terminal |
|---|---|
| Degree Of Protection | Closed type (cover) |
| Coil Resistance | 180 Ω |
| Operate Voltage Set Voltage | 80% max. |
| Release Voltage Reset Voltage | 30 % min. |
| Contact Rated Load | 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ = 0.4)) 24 VDC 3 A (Resistive load) 24 VDC 1.5 A (Inductive load (L/R = 7 ms)) |
| Max Contact Voltage | 250 VAC 125 VDC |
| Max Contact Current | AC: 3 A DC: 3 A |
| Maximum Switching Power | 660 VA (Resistive load) 176 VA (Inductive load (cosφ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) |
| Contact Method | Single |
| Contact Form | 4PDT |
| Mounting Method | Socket |
| Operating Indicator | LED |
| Coil Ratings | 24 VAC 50 Hz 53.8 mA 24 VAC 60 Hz 46 mA |
| Coil Maximum Voltage | 110 % (23 ℃) |
| Contact Material | Au clad + Ag alloy |
| Power Consumption | Approx. 0.9 to 1.3 VA 60 Hz |
| Contact Resistance | 50 mΩ max. (Voltage drop method with 5 VDC 1 A) |
| Operating Time | 20 ms max. (With rated operating power applied, not including contact bounce) |
| Reset Time | 20 ms max. (With rated operating power applied, not including contact bounce) |
| Maximum Operating Frequency | Mechanical: 18000 time/hour Rated load: 1800 time/hour |
| Ambient Temperature Operating | -55 to 60 ℃ (with no freezing or condensation) |
| Ambient Humidity Operating | 5 to 85% |
| Weight | Approx. 35 g |
Datasheet
Omron datasheetmy-datasheet.pdfOther models in this series
Compare MY4N AC24 with similar models in the same series. See all 120 models on the MY Series page.
| Model | Mounting Method | Contact Method | Max Contact Voltage | Release Voltage Reset Voltage |
|---|---|---|---|---|
| MY4N AC24 (this model) | Socket | Single | 250 VAC 125 VDC | 30 % min. |
| MY4N AC110/120 | Socket | Single | 250 VAC 125 VDC | 10 % min. |
| MY4N AC12 | Socket | Single | 250 VAC 125 VDC | 30 % min. |
| MY4N AC200/220 | Socket | Single | 250 VAC 125 VDC | 30 % min. |
| MY4N AC220/240 | socket | Single | 250 VAC 125 VDC | — |
| MY4N DC100/110 | Socket | Single | 250 VAC 125 VDC | 10 % min. |
| MY4N DC12 | Socket | Single | 250 VAC 125 VDC | 10 % min. |
| MY4N DC24 | Socket | Single | 250 VAC 125 VDC | 10 % min. |
| MY4N DC48 | Socket | Single | 250 VAC 125 VDC | 10 % min. |