Image for reference. Refer to the datasheet for exact dimensions.
Omron S8FS-G01512CD Power Supply
Omron S8FS-G01512CD Power Supply offers 15 W Power, 12 VDC Output voltage, 1.3 A Current, DIN rail, Screw Terminal, 100 to 240 VAC, 50/60 Hz Frequency.
- Brand
- Omron
- Model number
- S8FS-G01512CD
- Series
- S8FS-G Series
- Product type
- Power Supply
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Omron S8FS-G01512CD technical specifications
| Power rating | 15 W |
|---|---|
| Output voltage | 12 VDC |
| Rated output current | 1.3 A |
| Terminal type | Screw Terminal |
| Mounting method | DIN rail |
| Connection | Terminal blocks |
| Efficiency | 84 % typ.(at 100 VAC input) 84 % typ.(at 200 VAC input) 84 % typ.(at 230 VAC input) |
| Rated input voltage | 100 to 240 VAC |
| Rated input current | 0.32 A typ.(at 100 VAC input) 0.2 A typ.(at 200 VAC input) |
| Input Leakage current | 0.5 mA max.(at 100 VAC input) 1 mA max.(at 200 VAC input) |
| Input Frequency | 50/60 Hz |
| Output indicator | Yes (color: green) |
| Output voltage variable range | -10 to +15 % (With V.ADJ) |
| Start-up time | 1000 ms max.(at 100 VAC input) 1000 ms max.(at 200 VAC input) |
| Hold time | 14 ms typ.(at 100 VAC input) 70 ms typ.(at 200 VAC input) |
| Vibration resistance | 10 to 55 Hz, 4.5 G max., 0.375 mm single amplitude in each 3 directions for 2 hours |
| Shock resistance | 150 m/s2, in each 6 directions 3 times |
| Ambient temperature (Operating) | -20 to 70 ? |
| Ambient temperature (Storage) | -25 to 75 ? |
| Ambient humidity (OperatingStorage) | 90 %RH max. |
| Cooling fan | No |
| Weight | 250 g max. |
Overview
Omron S8FS-G01512CD SMPS is a compact 15 W switch mode power supply designed to provide 12 VDC with 1.3 A rated output current. Efficiency is specified at 84% typical with 100 VAC, 200 VAC, and 230 VAC input. Within the S8FS-G Series, the S8FS-G01512CD provides a DIN rail 15 W, 12 VDC configuration. Startup time is 1000 ms maximum at 100 VAC and 200 VAC, while hold time is 14 ms typical at 100 VAC and 70 ms typical at 200 VAC. For a direct-mount version providing the same 15 W, 12 VDC, and 1.3 A output, compare the Omron S8FS-G01512C .
Datasheet
Omron datasheets8fs-g-series.pdfOther models in this series
Compare S8FS-G01512CD with similar models in the same series. See all 74 models on the S8FS-G Series page.
| Model | Mounting method | Connection | Input Frequency | Output voltage |
|---|---|---|---|---|
| S8FS-G01512CD (this model) | DIN rail | Terminal blocks | 50/60 Hz | 12 VDC |
| S8FS-G01505C | Direct Mounting | Terminal blocks | 50/60 Hz | 5 VDC |
| S8FS-G01505CD | DIN rail | Terminal blocks | 50/60 Hz | 5 VDC |
| S8FS-G01512C | Direct Mounting | Terminal blocks | 50/60 Hz | 12 VDC |
| S8FS-G01515C | Direct Mounting | Terminal blocks | 50/60 Hz | 15 VDC |
| S8FS-G01515CD | DIN rail | Terminal blocks | 50/60 Hz | 15 VDC |
| S8FS-G01524C | Direct Mounting | Terminal blocks | 50/60 Hz | 24 VDC |
| S8FS-G01524CD | DIN rail | Terminal blocks | 50/60 Hz | 24 VDC |
| S8FS-G01524CE | DIN track | Connector | 50/60 Hz | 24 VDC |