Phoenix Contact MACX-TR-2T-MUL technical specifications
| Product type | Timer relay |
|---|---|
| Mechanical service life | Approx. 3x 107 cycles |
| Service life electrical | approx. 1x 105 cycles, resistive load 2000 V A |
| Nominal frequency | 48 Hz ... 63 Hz |
| Nominal power consumption | 2.5 VA (0.8 W) |
| Rated insulation voltage | 300 V AC |
| Input voltage range | 24 V AC/DC ... 240 V AC/DC (-15 % ... +10 %) |
| Temperature coefficient, typical | ≤ 0.01 %/°C |
| Recovery time | 100 ms |
| Setting range time | 10 ms ... 59999 min. (10 ms ... 999 h 59 min.) |
| Setting accuracy | ≤ 0.5 % (>1 s) |
| Repeat accuracy | ≤ 0.05 % (>1 s) |
| Maximum switching voltage | 400 V AC |
| Interrupting rating (ohmic load) max. | 2000 VA (8 A / 250 V AC) |
| Output fuse | 8 A (fast-blow) |
| Connection method | Screw connection |
| Stripping length | 10 mm |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Ambient temperature (operation) | -25 °C ... 60 °C |
Overview
The Phoenix MACX-TR-2T-MUL Time Relay (Part No: 1103345 ) offers a 24 V AC/DC ... The relay supports a wide input voltage range from 24 V AC/DC to 240 V AC/DC (with ±15% tolerance), allowing versatile integration into different control systems. This timer relay features a 100 ms recovery time , 8 A fast-blow fuse , and a maximum switching voltage of 400 V AC . Installation is secure and straightforward using screw terminals that accept 0.2 to 2.5 mm² rigid conductors with a 10 mm stripping length . The MACX-TR-2T-MUL is ideal for automation engineers managing complex sequential processes in industries like packaging, water treatment, material handling, and HVAC.
Datasheet
Phoenix Contact datasheetphoenix-contact-macx-tr-2t-mul-1103345.pdfOther models in this series
Compare MACX-TR-2T-MUL with similar models in the same series. See all 17 models on the Phoenix Time Relays page.
| Model | Connection method | Output fuse | Maximum switching voltage | Nominal power consumption |
|---|---|---|---|---|
| MACX-TR-2T-MUL (this model) | Screw connection | 8 A (fast-blow) | 400 V AC | 2.5 VA (0.8 W) |
| PLC-TR-1T-MUL-300M-PT | Push-in connection | 6.3 A (fast-blow) | 250 V AC | 0.45 W (at 24 V DC) |
| ETD-BL-1T-230 | Screw connection | 5 A (fast-blow) | 250 V AC (in acc. with IEC 60664-1) | 4 VA |
| TR-ES-OFF-CC-24/240-10H | Screw connection | 5 A (fast-blow) | 250 V AC | 8 VA (1 W, 230 V AC) |
| MACX-TR-1T-POFF-PT | Push-in connection | 8 A (fast-blow) | 400 V AC | 2.5 VA (0.8 W) |
| MACX-TR-1T-MUL-PT | Push-in connection | 8 A (fast-blow) | 400 V AC | 2.5 VA (0.8 W) |
| ETD-BL-1T-230-PT | Push-in connection | 5 A (fast-blow) | 250 V AC (in acc. with IEC 60664-1) | — |
| TR-ES-1T-MUL-10H | — | 5 A (fast-blow) | 250 V AC | — |
| ETD-BL-2T-I-230-PT | Push-in connection | 5 A (fast-blow) | 250 V AC (in acc. with IEC 60664-1) | 2.5 VA (1 W) |