IndMALL 2.0 preview — for review only, not indexed by search engines. Links reflect the live IndMALL site; WhatsApp buttons open the real IndMALL enquiry number.

Industrial automation products & suppliers across India

Phoenix Contact QTC 1,5-TWIN-TG - 3050413 - Disconnect terminal block

Image for reference. Refer to the datasheet for exact dimensions.

Phoenix Contact QTC 1,5-TWIN-TG - 3050413 - Disconnect terminal block

Obtain a Quote for Phoenix Contact Disconnect terminal block QTC 1,5-TWIN-TG, 3050413 at the lowest pricing.

Brand
Phoenix Contact
Model number
QTC 1,5-TWIN-TG
Series
Phoenix Disconnect Terminal Block

Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.

Phoenix Contact QTC 1,5-TWIN-TG technical specifications

Product typeDisconnect terminal block
Area of applicationRailway industry
DIN rail/fixing supportNS 35/15
Number of connections3
Number of rows1
Potentials1
Overvoltage categoryIII
Degree of pollution3
Rated surge voltage6 kV
Maximum power dissipation for nominal condition0.56 W
Number of connections per level3
Nominal cross section1.5 mm²
Connection in acc. with standardIEC 6094771
Conductor cross section rigid0.25 mm² ... 1.5 mm²
Cross section AWG24 ... 16 (converted acc. to IEC)
Conductor cross section flexible0.25 mm² ... 1.5 mm²
Conductor cross section, flexible [AWG]24 ... 16 (converted acc. to IEC)
Nominal current17.5 A
Maximum load current17.5 A (with 1.5 mm² conductor cross section)
Nominal voltage400 V
Width5.2 mm
End cover width2.2 mm
Height94 mm
Depth on NS 35/7,539.3 mm
Depth on NS 35/1546.8 mm
Colorgray (RAL 7042)
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold60 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 HL 3
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Test voltage setpoint1.89 kV
ResultTest passed
Requirement temperature-rise testIncrease in temperature ≤ 45 K
Open side panelYes
DIN rail/fixing supportNS 35
Test force setpoint1 N
Rotation speed10 rpm
Revolutions135
Conductor cross section/weight0.2 mm² / 0.2 kg
Temperature cycles192
Time of exposure30 s
Ambient temperature (operation)60 °C ... 110 °C (Operating temperature range incl. selfheating; for max. shortterm operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)25 °C ... 60 °C (for a short time, not exceeding 24 h, 60 °C to +70 °C)
Ambient temperature (assembly)5 °C ... 70 °C
Ambient temperature (actuation)5 °C ... 70 °C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %
Mounting typeNS 35/7,5
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Short-time withstand current 1.5 mm²0.18 kA
Depth39.3 mm
GeneralThe max. load current must not be exceeded by the total current of all connected conductors. Current and voltage are determined by the plug used.
Frequency of connections with the same cross section100
Material wire insulationPVC / PE
Wire diameter incl. insulation3 mm
Specifications as listed by IndMALL. Confirm against the manufacturer's datasheet before ordering.

Overview

Technical Specifications of Disconnect terminal block QTC 1,5-TWIN-TG 3050413

Other models in this series

Compare QTC 1,5-TWIN-TG with similar models in the same series. See all 300 models on the Phoenix Disconnect Terminal Block page.

QTC 1,5-TWIN-TG compared with other models in the series
ModelNumber of connectionsNumber of connections per levelOvervoltage categoryRated surge voltage
QTC 1,5-TWIN-TG (this model)33III6 kV
UDMTK 5-P/P42III4 kV
303843522III6 kV
UDK 4-MTK-P/P44III8 kV
UK 5-MTK-P/P BU22III6 kV
321018522III6 kV
UT 4-HEDI22III6 kV
PT 2,5-QUATTRO-TGB44III6 kV
PT 4-MT BU22III6 kV