Phoenix Contact UT 2,5-MT RD - 1132641 - Disconnect terminal block
IndMALL Automation Offers Phoenix Contact Disconnect terminal block UT 2,5-MT RD, 1132641 with exclusive offers.
- Brand
- Phoenix Contact
- Model number
- UT 2,5-MT RD
- Series
- Phoenix Disconnect Terminal Block
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Phoenix Contact UT 2,5-MT RD technical specifications
| Product type | Disconnect terminal block |
|---|---|
| Area of application | Railway industry |
| DIN rail/fixing support | NS 35/15 |
| Number of connections | 2 |
| Number of rows | 1 |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Rated surge voltage | 6 kV |
| Maximum power dissipation for nominal condition | 0.77 W |
| Number of connections per level | 2 |
| Nominal cross section | 2.5 mm² |
| Stripping length | 9 mm |
| Internal cylindrical gage | A3 |
| Connection in acc. with standard | IEC 6094771 |
| Conductor cross section rigid | 0.14 mm² ... 4 mm² |
| Cross section AWG | 26 ... 12 (converted acc. to IEC) |
| Conductor cross section flexible | 0.14 mm² ... 4 mm² |
| Conductor cross section, flexible [AWG] | 26 ... 12 (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.14 mm² ... 2.5 mm² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.14 mm² ... 2.5 mm² |
| 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 1.5 mm² |
| Nominal current | 20 A (with 4 mm² conductor cross section) |
| Maximum load current | 20 A (with 4 mm² conductor cross section) |
| Nominal voltage | 400 V |
| Width | 5.2 mm |
| End cover width | 2.2 mm |
| Height | 57.8 mm |
| Depth on NS 35/7,5 | 49.1 mm |
| Depth on NS 35/15 | 56.6 mm |
| Color | red (RAL 3001) |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Static insulating material application in cold | 60 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Open side panel | Yes |
| Ambient temperature (operation) | 60 °C ... 110 °C (Operating temperature range incl. selfheating; for max. shortterm operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | 25 °C ... 60 °C (for a short time, not exceeding 24 h, 60 °C to +70 °C) |
| Ambient temperature (assembly) | 5 °C ... 70 °C |
| Ambient temperature (actuation) | 5 °C ... 70 °C |
| Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Mounting type | NS 35/7,5 |
| Screw thread | M3 |
| Tightening torque | 0.5 ... 0.6 Nm |
| 2 conductors with same cross section, solid | 0.14 mm² ... 1.5 mm² |
| 2 conductors with same cross section, flexible | 0.14 mm² ... 1.5 mm² |
| 2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.14 mm² ... 1.5 mm² |
| Rated cross section AWG | 12 |
Overview
Technical Specifications of Disconnect terminal block UT 2,5-MT RD 1132641
Other models in this series
Compare UT 2,5-MT RD with similar models in the same series. See all 300 models on the Phoenix Disconnect Terminal Block page.
| Model | Number of connections | Number of connections per level | Overvoltage category | Rated surge voltage |
|---|---|---|---|---|
| UT 2,5-MT RD (this model) | 2 | 2 | III | 6 kV |
| PT 1,5/S-TG | 2 | 2 | III | 6 kV |
| UK 5-MTK-P/P YE | 2 | 2 | III | 6 kV |
| 3046144 | 2 | 2 | III | 6 kV |
| UT 6-MTL KNIFE-RD | 2 | 2 | III | 6 kV |
| PT 1,5/S-QUATTRO-TG BU | 4 | 4 | III | — |
| 3048467 | 4 | 2 | III | 4 kV |
| UTTB 4-TG P/P | 4 | 2 | III | 6 kV |
| UT 4-QUATTRO-MT P/P BU | 4 | 4 | III | 6 kV |