Image for reference. Refer to the datasheet for exact dimensions.
Puls ML90.200 Power Supply
Ask for the Pricing of Puls 3 Phase Power Supplies ML90.200 at affordable rates. 0.6, 24 Vdc, 90 W, DIN rail.
- Brand
- Puls
- Model number
- ML90.200
- Series
- Puls DIN Rail Power Supply
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Puls ML90.200 technical specifications
| AC Input voltage | AC 380 - 480 V (± 15 %) |
|---|---|
| Harmonic correction | - |
| Power factor | 0.6 |
| Input inrush current limitation | NTC |
| Input inrush current | 30 A / 36 A |
| External input fuse recommendation | B-10 A / C-6 A |
| Nominal voltage | 24 Vdc |
| Adjustment range | 24 - 28 V |
| Output current range | 3.8 - 3.2 A |
| Output current | 3.2 A at 28 V |
| Output power | 90 W |
| Derating | 2 W/°C for >+60 °C |
| Ripple and noise voltage max. | 50 mVpp |
| Dimensions (WxHxD) | 73 mm x 75 mm x 103 mm |
| Weight per unit (excl. packaging) | 360 g |
| Mounting method | DIN rail |
| Operating temp. range | - |
| Connection method | Spring clamps |
| Efficiency, typ. | 89.5 % |
| Power losses, typ. | 10.5 W |
Overview
The Puls ML90.200 Power Supply offers 24 Vdc, DIN rail Mounting Method, Spring clamps Connection Method, 3.2 A at 28 V output current. The Puls ML90.200 operates on a wide AC input voltage of 380–480 V (±15%) and delivers a nominal 24 Vdc output adjustable up to 28 V. Key features include NTC inrush current limitation , input fuse recommendations (B-10 A / C-6 A), and derating protection of 2 W/°C above +60 °C. Many also review the ML90.200 price when comparing options, but the Puls ML90.200 is recognized globally for efficiency, compact size, and robust design.
Datasheet
Puls datasheetml90-200.pdfOther models in this series
Compare ML90.200 with similar models in the same series. See all 193 models on the Puls DIN Rail Power Supply page.
| Model | Mounting method | Operating temp. range | Output current range | Connection method |
|---|---|---|---|---|
| ML90.200 (this model) | DIN rail | - | 3.8 - 3.2 A | Spring clamps |
| CT5.241 | DIN rail | -25 °C to 70 °C | 5 - 4.3 A | Screw terminals |
| CT10.241 | DIN rail | -25 °C to 70 °C | 10 - 8.6 A | Screw terminals |
| CT10.241-C1 | DIN rail | -25 °C to 70 °C | 10 - 8.6 A | Screw terminals |
| CT10.481 | DIN rail | -25 °C to 70 °C | 5 - 4.3 A | Screw terminals |
| ML100.200 | DIN rail | - | 4.2 - 3.6 A | Spring clamps |
| QT20.241 | DIN rail | -25 °C to 70 °C | 20 - 17.5 A | Spring clamps |
| QT20.241-C1 | DIN rail | -25 °C to 70 °C | 20 - 17.5 A | Spring clamps |
| QT20.361 | DIN rail | -25 °C to 70 °C | 13.3 - 11.4 A | Spring clamps |