Image for reference. Refer to the datasheet for exact dimensions.
Schmersal AZ 16-12ZIB1-M20-2053 Safety Switch with Separate Actuator
IndMALL provides Schmersal AZ 16-12ZIB1-M20-2053, Item 101150635, Safety Switch with Heavy-Duty Thermoplastic Casing. Reliable protection.
- Brand
- Schmersal
- Model number
- AZ 16-12ZIB1-M20-2053
- Series
- AZ Series
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schmersal AZ 16-12ZIB1-M20-2053 technical specifications
| Working principle | Electromechanical |
|---|---|
| Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Number of safety contacts | 2 |
| Number of cable glands | 3 |
| B10D Normally-closed contact (NC) | 2,000,000 Operations |
| B10D Normally-open contact (NO) | 1,000,000 Operations |
| Latching force | - |
| Positive break travel | 8 mm |
| Positive break force per NC contact, minimum | 10 N |
| Positive break force, minimum | 20 N |
| Actuating speed, maximum | 2 m/s |
| Mounting | Screws |
| Type of the fixing screws | 2x M6 |
| Termination | Screw terminals |
| Cable entry | 3 x M20 x 1,5 |
| Cable section, minimum | 0.25 mm² 0.75 mm² |
| Cable section, maximum | 2.5 mm² |
| Allowed type of cable | solid single-wire solid multi-wire flexible |
| Length of sensor | 30 mm |
| Width of sensor | 52 mm |
| Height of sensor | 90 mm |
| Degree of protection | IP67 |
| Ambient temperature | -30 ... +80 °C |
| Storage and transport temperature | -40 ... +85 °C |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6 kV |
| Thermal test current | 10 A |
| Required rated short-circuit current | 1,000 A |
| Switching element | 1 NO contact, 2 NC contacts |
| Switching principle | slow action, positive break NC contact |
| Maximum switching frequency | 4,000 /h |
| Material of the contacts, electrical | Silver |
| Gross weight | 195 g |
Datasheet
Schmersal datasheetschmersal-az-16-12zib1-m20-2053-101150635.pdfOther models in this series
Compare AZ 16-12ZIB1-M20-2053 with similar models in the same series. See all 184 models on the AZ Series page.
| Model | Rated impulse withstand voltage Uimp | Required rated short-circuit current | Thermal test current | Number of safety contacts |
|---|---|---|---|---|
| AZ 16-12ZIB1-M20-2053 (this model) | 6 kV | 1,000 A | 10 A | 2 |
| AZ 16-12ZIB1-M20-1747 | 6 kV | 1,000 A | 10 A | 2 |
| AZ 16-03ZIB1-M16-1747 | 6 kV | 1,000 A | 10 A | 3 |
| AZ 16-12ZI-ST-B1-2053 | 0.8 kV | 1,000 A | 10 A | 2 |
| AZ 16-12ZIB1-M16-2053 | 6 kV | 1,000 A | 10 A | 2 |
| AZ 16-03ZIB1-M20-2053 | 6 kV | 1,000 A | 10 A | 3 |
| AZ 16-03ZIB1-M16-2053 | 6 kV | 1,000 A | 10 A | 3 |
| AZ 16-03ZIB1-M16-2177 | 6 kV | 1,000 A | 10 A | 3 |
| AZ 16-03ZIB1-M16-2024 | 6 kV | 1,000 A | 10 A | — |