Image for reference. Refer to the datasheet for exact dimensions.
Schmersal AZ 17-02ZRI B6R Safety Switch with Separate Actuator
IndMALL delivers Schmersal AZ 17-02ZRI B6R, Item 101136310, Universal Coding Thermoplastic Safety Switch. Secure and efficient for diverse setups.
- Brand
- Schmersal
- Model number
- AZ 17-02ZRI B6R
- Series
- AZ Series
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schmersal AZ 17-02ZRI B6R technical specifications
| Working principle | Electromechanical |
|---|---|
| Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Number of safety contacts | 2 |
| Number of cable glands | 1 |
| B10D Normally-closed contact (NC) | 2,000,000 Operations |
| Latching force | - |
| Positive break travel | 11 mm |
| Positive break force per NC contact, minimum | 17 N |
| Positive break force, minimum | 34 N |
| Actuating speed, maximum | 2 m/s |
| Mounting | Screws |
| Type of the fixing screws | 2x M5 |
| Cable entry | M 16 x 1.5 |
| Cable section, minimum | 0.75 mm² |
| Cable section, maximum | 1 mm² |
| Allowed type of cable | flexible |
| Length of sensor | 30 mm |
| Width of sensor | 30 mm |
| Height of sensor | 85 mm |
| Degree of protection | IP67 |
| Ambient temperature | -30 ... +80 °C |
| Storage and transport temperature | -30 ... +85 °C |
| Rated insulation voltage Ui | 250 VAC |
| Rated impulse withstand voltage Uimp | 4 kV |
| Thermal test current | 10 A |
| Required rated short-circuit current | 1,000 A |
| Switching element | 2 NC contact |
| Switching principle | slow action, positive break NC contact |
| Maximum switching frequency | 2,000 /h |
| Material of the contacts, electrical | Silver |
| Gross weight | 115 g |
Datasheet
Schmersal datasheetschmersal-az-17-02zri-b6r-101136310.pdfOther models in this series
Compare AZ 17-02ZRI B6R with similar models in the same series. See all 184 models on the AZ Series page.
| Model | Rated impulse withstand voltage Uimp | Required rated short-circuit current | Thermal test current | Number of safety contacts |
|---|---|---|---|---|
| AZ 17-02ZRI B6R (this model) | 4 kV | 1,000 A | 10 A | 2 |
| AZ 17-02ZI B6L | 4 kV | 1,000 A | 10 A | 2 |
| AZ 17-02ZRI B6L | 4 kV | 1,000 A | 10 A | 2 |
| AZ 17-11ZI-ST B6L | 4 kV | 1,000 A | 10 A | 1 |
| AZ 17-11ZRI B6L | 4 kV | 1,000 A | 10 A | 1 |
| AZ 17-11ZRI-ST B6R | 4 kV | 1,000 A | 10 A | 1 |
| AZ 17-11ZI B6R | 4 kV | 1,000 A | 10 A | 1 |
| AZ 17-02ZI B6R | 4 kV | 1,000 A | 10 A | 2 |
| AZ 17-11ZRI B6R | 4 kV | 1,000 A | 10 A | 1 |