Image for reference. Refer to the datasheet for exact dimensions.
ATS130N2D38LT: Schneider Altivar Soft Starter
Schneider ATS130N2D38LT, Altivar Soft Starter ATS130. Reliable control—request your IndMALL quote today for efficient soft starter solutions.
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider ATS130N2D38LT technical specifications
| Power supply frequency | 50...60 Hz +/- 5 Hz |
|---|---|
| Operating cycles/hour | 50 cyc/h |
| Maximum deflection under vibratory load (during transport) | 3 mm at 2-9 Hz |
| Maximum acceleration under vibratory load (during storage) | 10 m/s² at 9...200 Hz |
| Height | 166 mm |
| Relay output number | 1 |
| Display type | 1 LED (green) for control power energized1 LED (yellow and red) for motor operation phases, errors |
| Pollution degree | Level 2 |
| Minimum motor current | 20 % Ie |
| Protection type | Phase failure: mainsThermal protection: starterBypass error: starterControl voltage Us: starter |
| Package 1 Length | 27.500 cm |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 9...200 Hz |
| Environmental class (during operation) | Without salt mist: 3C3 conforming to IEC 60721-3-33S3 conforming to IEC 60721-3-3 |
| Suitable for mounting onto standard rails | TRUE |
| Overload current profile | 300 % Ie for 5 s |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Function available | Deceleration voltage rampBoost |
| Minimum switching current | 2.5 mA at 24 V DC for relay outputs |
| Operating altitude | 0...1000 m without derating1000...4000 m 1 % per 100 m |
| Package 1 Weight | 1.510 kg |
| Motor power hp | 10 hp at 200 V normal duty10 hp at 208 V normal duty10 hp at 230 V normal duty25 hp at 460 V normal duty |
| IP degree of protection | IP20 |
| Ambient air transport temperature | -40…70 °C |
| Product or component type | Soft starter |
| Utilisation category | AC-53A |
| Ue power supply voltage | 200...480 V - 15...10 % |
| Maximum switching current | On resistive load for relay outputs : 1 A 250 V AC 400000 cyclesOn resistive load for relay outputs : 1 A 30 V DC 400000 cyclesOn inductive load for relay outputs : 1 A 250 V AC cos phi = 0.4 100000 cyclesOn inductive load for relay outputs : 1 A 30 V DC cos phi = 0.4 100000 cycles |
| Depth | 165 mm |
| Operating position | Vertical +/- 30 degree |
| [Ui] rated insulation voltage | 480 V |
| Network number of phases | 3 phases |
| Input compatibility | Discrete input level 1 PLC conforming to EN/IEC 61131-2 |
| Device connection | In line |
| Width | 55 mm |
| Torque control | FALSE |
| Ambient air temperature for storage | -25…70 °C |
| Control power | 21.6 W starting and stopping3 W steady state |
| Range of product | Altivar Soft Starter ATS130 |
| [Uc] control circuit voltage | 24 V DC |
| Relative humidity | 5…95 % non condensing without dripping water conforming to IEC 60068-2-3 |
| Power loss per device current dependent | 7 W |
| Net weight | 1.3 kg |
| [Ie] rated operational current | 38 A in line (at <40 °C) |
| Maximum deflection under vibratory load (during storage) | 3 mm at 2-9 Hz |
| Ambient air temperature for operation | -10…40 °C (without derating)40…60 °C (with current derating 1.5 % per °C) |
| Motor power kW | 11 kW at 230 V normal duty18.5 kW at 400 V normal duty22 kW at 440 V normal duty |
| Power loss static current independent | 3 W |
| Power loss during starting | 220 W 300 % Ie |
| Relay output type | Relay outputs R1A, R1C NO |
| Number of Units in Package 1 | 1 |
Overview
The ATS130N2D38LT is a compact and efficient soft starter from Schneider Electric , part of the trusted Schneider Altivar Soft Starter ATS130 series. The Schneider ATS130N2C11LT is a powerful 105 A soft starter that supports a 3-phase network and operates on a wide supply range of 200–480 V . Its compact form factor (81 mm width, 197 mm height, and 180 mm depth) and light weight ( 2.3 kg ) make it a perfect fit for space-constrained panels. With control circuit voltage at 24 V DC and energy-efficient standby power usage (only 3 W ), the Schneider ATS130N2C11LT helps optimize both operational costs and system integration.
Datasheet
Schneider datasheetschneider-electric-ats130n2d38lt.pdfOther models in this series
Compare ATS130N2D38LT with similar models in the same series. See all 27 models on the Altivar Soft Starter page.
| Model | Range of Product | Relay output number | Power supply frequency | Ue power supply voltage |
|---|---|---|---|---|
| ATS130N2D38LT (this model) | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS480C66Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480C79Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480M10Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480M12Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS130N2D45LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS130N2D65LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS130N2D73LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS130N2D80LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |