Image for reference. Refer to the datasheet for exact dimensions.
ATV340U30N4E - Schneider Electic 3kW Ethernet VSD
Schneider ATV340U30N4E, 3kW Ethernet VSD. Ensure stable control—get your IndMALL quote today for efficient Schneider Electric drive solutions.
- Brand
- Schneider
- Model number
- ATV340U30N4E
- Series
- Schneider Altivar Machine ATV340
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider ATV340U30N4E technical specifications
| Analogue input number | 22 |
|---|---|
| Motor power hp | 3 hp for heavy duty5 hp for normal duty |
| Protection type | Thermal protection: motorSafe torque off: motorMotor phase loss: motorThermal protection: driveSafe torque off: driveOverheating: driveOvercurrent: driveOutput overcurrent between motor phase and earth: driveOutput overcurrent between motor phases: driveShort-circuit between motor phase and earth: driveShort-circuit between motor phases: driveMotor phase loss: driveDC Bus overvoltage: driveLine supply overvoltage: driveLine supply undervoltage: driveInput supply loss: driveExceeding limit speed: driveBreak on the control circuit: drive |
| Network number of phases | 3 phases |
| Electrical connection | Line side: screw terminal 1.5...4 mm²/AWG 14...AWG 12DC bus: screw terminal 4...6 mm²/AWG 12...AWG 10Motor: screw terminal 1.5...4 mm²/AWG 14...AWG 12Control: screw terminal 0.2...2.5 mm²/AWG 24...AWG 12 |
| Continuous output current | 9.3 A at 4 kHz for normal duty7.2 A at 4 kHz for heavy duty |
| Overvoltage category | Class III |
| Noise level | 51.2 dB |
| Analogue output number | 1 |
| Degree of protection | - |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3Class 3S3 according to IEC 60721-3-3 |
| [Us] rated supply voltage | 380...480 V - 15...10 % |
| Standards | IEC 61800-3IEC 61800-5-1IEC 60721-3IEC 61508IEC 13849-1UL 618000-5-1UL 508C |
| Relay output number | 2 |
| Ambient air temperature for operation | -15…50 °C without derating (vertical position)50…60 °C with derating factor (vertical position) |
| Discrete input number | 5 |
| Product certifications | ULCSATÜVEACCTick |
| Type of cooling | Forced convection |
| Net weight | 2.2 kg |
| EMC filter | Class C3 EMC filter integrated |
| Communication port protocol | Modbus serialModbus TCPEtherNet/IP |
| Supply frequency | 50...60 Hz +/- 5 % |
| Mounting mode | Cabinet mount |
| Discrete output number | 2 |
| Connector type | 3 RJ45 |
Overview
Technical specificatons of Schneider Electic 3kW Ethernet VSD ATV340U30N4E: Call us for Schneider Electric 3kW Ethernet VSD ATV340U30N4E at the best rates! The adjustable switching frequency range is from 2...16 kHz, with a derating factor of 7...16 kHz. The continuous output current is 9.3 A at 4 kHz for normal duty and 7.2 A at 4 kHz for heavy duty, with a maximum input current of 10.7 A. Operating on a supply frequency of 50...60 Hz +/- 5 %, it features a 2-wire RS 485 physical interface and includes 3 RJ45 connectors for seamless connectivity. Request the ATV340U30N4E Price and get a custom quote for your ATV340U30N4E Manual .
Datasheet
Schneider datasheetschneider-electric-atv340u30n4e.pdfOther models in this series
Compare ATV340U30N4E with similar models in the same series. See all 12 models on the Schneider Altivar Machine ATV340 page.
| Model | Analogue input number | Analogue output number | Discrete input number | Discrete output number |
|---|---|---|---|---|
| ATV340U30N4E (this model) | 22 | 1 | 5 | 2 |
| ATV340U07N4E | 22 | 1 | 5 | 2 |
| ATV340U15N4E | 22 | 1 | 5 | 2 |
| ATV340U22N4E | 22 | 1 | 5 | 2 |
| ATV340U40N4E | 22 | 1 | 5 | 2 |
| ATV340U55N4E | 22 | 1 | 5 | 2 |
| ATV340U75N4E | 22 | 1 | 5 | 2 |
| ATV340D11N4E | 22 | 1 | 5 | 2 |
| ATV340D15N4E | 22 | 1 | 5 | 2 |