Image for reference. Refer to the datasheet for exact dimensions.
Schneider ATV6A0C20T4 Variable Speed Drive
Schneider ATV6A0C20T4, 300 HP Variable Speed Drive. Enhance performance—reach out to IndMALL for pricing and optimize your system today.
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider ATV6A0C20T4 technical specifications
| Degree of protection | - |
|---|---|
| Supply frequency | 50...60 Hz - 5...5 % |
| Vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-60.5 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
| IP degree of protection | IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529 |
| Speed drive output frequency | 0…500 Hz |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-41.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Product or component type | Variable speed drive |
| Output voltage | <= power supply voltage |
| Asynchronous motor control profile | Constant torque standardVariable torque standardOptimized torque mode |
| Mounting mode | Cabinet mount |
| Ambient air temperature for storage | -40…70 °C |
| Continuous output current | 370.0 A at 2.5 kHz normal duty302.0 A at 2.5 kHz heavy duty |
| Relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Electrical connection | Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16Line side: screw terminalMotor: M10 x 2 bars |
| Synchronous motor control profile | Permanent magnet motor |
| Physical interface | 2-wire RS 485 for Modbus serial |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Type of polarization | No impedance for Modbus serial |
| Product destination | Synchronous motorsAsynchronous motors |
| Number of preset speeds | 16 preset speeds |
| Operating altitude | <= 1000 m without derating1000...4800 m with current derating 1 % per 100 m |
| Apparent power | 273 kVA at 480 V normal duty233 kVA at 480 V heavy duty |
| [Us] rated supply voltage | 480 V - 15...10 % |
| Ambient air temperature for operation | -10…40 °C without derating40…50 °C with derating factor |
| Supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protectionInternal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection |
| Switching frequency | 2.5...8 kHz with derating factor2...8 kHz adjustable |
| Motor power kW | 200.0 kW at 480 V normal duty160.0 kW at 480 V heavy duty |
| EMC filter | Integrated with 300 m conforming to IEC 61800-3 category C3 |
| Communication port protocol | EthernetModbus serialModbus TCP |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits |
| Maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Range of product | Altivar Process ATV600 |
| Shock resistance | 7 gn for 11 ms conforming to IEC 60068-2-27 |
| Power dissipation in W | Forced convection: 4810 W, switching frequency 2.5 kHz (normal duty)Forced convection: 3830 W, switching frequency 2.5 kHz (heavy duty) |
| Nominal switching frequency | 2.5 kHz |
| Motor power hp | 300.0 hp at 480 V normal duty250.0 hp at 480 V heavy duty |
| Network number of phases | 3 phases |
Overview
The Schneider ATV6A0C20T4 Variable Speed Drive offers a 200.0 kW at 480 V normal duty160.0 kW at 480 V heavy duty motor power, 2-wire RS 485 for Modbus serial , 3 phases . Essential Technical Specs of ATV6A0C20T4 are Altivar Process ATV600 range, with top-notch specifications. The supply frequency is 50...60 Hz - 5...5 %, while the speed drive output frequency ranges from 0…500 Hz, ensuring flexibility in applications. The sensor operates at altitudes below <= 1000 m without derating1000...4800 m with current derating 1 % per 100 m. The switching frequency is adjustable between 2.5...8 kHz with derating factor2...8 kHz adjustable, providing precise control.
Datasheet
Schneider datasheetschneider-electric-atv6a0c20t4.pdfOther models in this series
Compare ATV6A0C20T4 with similar models in the same series. See all 106 models on the Altivar ATV600 page.
| Model | Range of product | [Us] rated supply voltage | Minimum switching current | Communication port protocol |
|---|---|---|---|---|
| ATV6A0C20T4 (this model) | Altivar Process ATV600 | 480 V - 15...10 % | Relay output R1, R2, R3: 5 mA at 24 V DC | EthernetModbus serialModbus TCP |
| ATV6A0C20Q4 | Altivar Process ATV600 | 400 V - 15...10 % | Relay output R1, R2, R3: 5 mA at 24 V DC | EthernetModbus serialModbus TCP |
| ATV6A0C20Q6 | Altivar Process ATV600 | 690 V - 15...10 % | - | EthernetModbus serialModbus TCP |
| ATV6A0C20R4 | Altivar Process ATV600 | 440 V - 15...10 % | Relay output R1, R2, R3: 5 mA at 24 V DC | EthernetModbus serialModbus TCP |
| ATV6A0C20S6 | Altivar Process ATV600 | 600 V - 15...10 % | - | EthernetModbus serialModbus TCP |
| ATV6A0C20T6 | Altivar Process ATV600 | 600 V - 15...10 % | - | EthernetModbus serialModbus TCP |
| ATV6A0C25N6 | Altivar Process ATV600 | 500 V - 10...15 % | - | EthernetModbus serialModbus TCP |
| ATV6A0C25Q4 | Altivar Process ATV600 | 400 V - 15...10 % | Relay output R1, R2, R3: 5 mA at 24 V DC | EthernetModbus serialModbus TCP |