Image for reference. Refer to the datasheet for exact dimensions.
LP1K06103BD: Schneider Tesys K NO Contactor 6A
Schneider LP1K06103BD, Tesys K NO Contactor 6A. Improve reliability—get a quote from IndMALL today for efficient industrial control solutions.
- Brand
- Schneider
- Model number
- LP1K06103BD
- Series
- Schneider Contactors TeSys K Contactors
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider LP1K06103BD technical specifications
| Connections - terminals | Spring terminals 1 cable(s) 0.75…1.5 mm²solidSpring terminals 1 cable(s) 0.75…1.5 mm²flexible without cable endSpring terminals 2 cable(s) 0.75…1.5 mm²flexible without cable end |
|---|---|
| [Uc] control circuit voltage | 24 V DC |
| Minimum switching voltage | 17 V for signalling circuit |
| contactor application | Motor control |
| Width | 45 mm |
| Control circuit type | DC standard |
| Average impedance | 3 mOhm - Ith 16 A 50 Hz for power circuit |
| Depth | 57 mm |
| [Ie] rated operational current | 6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| Auxiliary contacts type | type instantaneous 1 NO |
| poles description | 3P |
| Auxiliary contact composition | 1 NO |
| IP degree of protection | IP2X |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Signalling circuit: 600 V conforming to UL 508Power circuit: 600 V conforming to CSA C22.2 No 14Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
| Operating altitude | 2000 m without derating |
| Ambient air temperature for operation | -25…50 °C |
| Power pole contact composition | 3 NO |
| Hold-in power consumption in W | 3 W at 20 °C |
| Ambient air temperature for storage | -50…80 °C |
| Utilisation category | AC-3AC-3eAC-4 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Heat dissipation | 1.3 W |
| Hold-in power consumption in VA | - |
| Net weight | 0.225 kg |
| Minimum switching current | 5 mA for signalling circuit |
| Mounting support | RailPlate |
| Operating time | 30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO opening |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
| Product or component type | Contactor |
| Tightening torque | - |
| Maximum operating rate | 3600 cyc/h |
| Range | TeSys |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC <= 400 HzSignalling circuit: <= 690 V AC <= 400 Hz |
| Height | 58 mm |
| Motor power kW | 1.5 kW at 220...230 V AC 50/60 Hz AC-32.2 kW at 380...415 V AC 50/60 Hz AC-33 kW at 440/690 V AC 50/60 Hz AC-31.5 kW at 220...230 V AC 50/60 Hz AC-3e2.2 kW at 380...415 V AC 50/60 Hz AC-3e3 kW at 440/690 V AC 50/60 Hz AC-3e1.5 kW at 220...230 V AC 50/60 Hz AC-42.2 kW at 380...415 V AC 50/60 Hz AC-43 kW at 440/690 V AC 50/60 Hz AC-4 |
| Inrush power in W | 3 W (at 20 °C) |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Electrical durability | 1.3 Mcycles 6 A AC-3 at Ue <= 440 V1.3 Mcycles 6 A AC-3e at Ue <= 440 V0.05 Mcycles 36 A AC-4 at Ue <= 440 V |
| Device short name | LP1K |
Overview
Technical Specifications of Schneider Tesys K NO Contactor 6A LP1K06103BD: Ask for the Pricing of Schneider Tesys K NO Contactor 6A LP1K06103BD at unbeatable prices. Detailed Specifications of LP1K06103BD features control circuit voltage [Uc] operates at 24 V DC, with a minimum switching voltage of 17 V for signalling circuit, ensuring responsive operation. It is suitable for both motor Motor control applications. The sensor features a 3P design and operates at altitudes up to 2000 m without derating, ensuring versatility across various environments. Heat dissipation 1.3 W, it is energy efficient. Now's the Time to Secure a Quote for your requirement of Schneider Tesys K NO Contactor 6A.
Datasheet
Schneider datasheetschneider-electric-lp1k06103bd.pdfOther models in this series
Compare LP1K06103BD with similar models in the same series. See all 120 models on the Schneider Contactors TeSys K Contactors page.
| Model | [Uc] control circuit voltage | Minimum switching voltage | Hold-in power consumption in VA | Hold-in power consumption in W |
|---|---|---|---|---|
| LP1K06103BD (this model) | 24 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LC1K1610P7 | 230 V AC 50/60 Hz | 17 V for signalling circuit | 4.5 VA (at 20 °C) | - |
| LC1K1610U7 | 230...240 V AC 50/60 Hz | 17 V for signalling circuit | 4.5 VA (at 20 °C) | - |
| LP1K0601BD3 | 24 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K0601FD | 110 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K06103BD3 | 24 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K0610JD | 12 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K090085BD | 24 V DC | - | - | 3 W at 20 °C |
| LP1K090085MD | 220 V DC | - | - | 3 W at 20 °C |