Schneider LP1K0910GD technical specifications
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solidScrew clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable endScrew clamp terminals 2 cable(s) 1.5…4 mm²solidScrew clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end |
|---|---|
| [Uc] control circuit voltage | 125 V DC |
| Minimum switching voltage | 17 V for signalling circuit |
| contactor application | Motor controlResistive load |
| Width | 45 mm |
| Control circuit type | DC standard |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| Depth | 57 mm |
| [Ie] rated operational current | 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit |
| Auxiliary contacts type | type instantaneous 1 NO |
| poles description | 3P |
| Auxiliary contact composition | 1 NO |
| IP degree of protection | IP2X |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Signalling circuit: 600 V conforming to UL 508Power circuit: 600 V conforming to CSA C22.2 No 14Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
| Operating altitude | 2000 m without derating |
| Ambient air temperature for operation | -25…50 °C |
| Power pole contact composition | 3 NO |
| Hold-in power consumption in W | 3 W at 20 °C |
| Ambient air temperature for storage | -50…80 °C |
| Utilisation category | AC-3AC-3eAC-1AC-4 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Heat dissipation | 1.3 W |
| Hold-in power consumption in VA | - |
| Net weight | 0.225 kg |
| Minimum switching current | 5 mA for signalling circuit |
| Mounting support | PlateRail |
| Operating time | 30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO opening |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
| Product or component type | Contactor |
| Tightening torque | 0.8…1.3 N.m - on screw clamp terminals Philips No 20.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm0.8…1.3 N.m - on screw clamp terminals pozidriv No 2 |
| Maximum operating rate | 3600 cyc/h |
| Range | TeSys |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC <= 400 HzSignalling circuit: <= 690 V AC <= 400 Hz |
| Height | 58 mm |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-34 kW at 380...415 V AC 50/60 Hz AC-34 kW at 440/690 V AC 50/60 Hz AC-32.2 kW at 220...230 V AC 50/60 Hz AC-3e4 kW at 380...415 V AC 50/60 Hz AC-3e4 kW at 440/690 V AC 50/60 Hz AC-3e2.2 kW at 220...230 V AC 50/60 Hz AC-44 kW at 380...415 V AC 50/60 Hz AC-44 kW at 440/690 V AC 50/60 Hz AC-4 |
| Inrush power in W | 3 W (at 20 °C) |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Electrical durability | 1.3 Mcycles 9 A AC-3 at Ue <= 440 V1.3 Mcycles 9 A AC-3e at Ue <= 440 V0.16 Mcycles 20 A AC-1 at Ue <= 690 V0.02 Mcycles 54 A AC-4 at Ue <= 440 V |
| Device short name | LP1K |
Overview
Technical Specifications of Schneider 125V DC TeSys K Contactor LP1K0910GD: Call us for Schneider 125V DC TeSys K Contactor LP1K0910GD at the best rates. Technical Attributes of LP1K0910GD are control circuit voltage [Uc] operates at 125 V DC, with a minimum switching voltage of 17 V for signalling circuit, ensuring responsive operation. It is suitable for both motor Motor controlResistive load applications. The sensor features a 3P design and operates at altitudes up to 2000 m without derating, ensuring versatility across various environments. Heat dissipation 1.3 W, it is energy efficient. Trust in our ability to provide more advantageous pricing and dedicated support beyond other other Dealers.
Datasheet
Schneider datasheetschneider-electric-lp1k0910gd.pdfOther models in this series
Compare LP1K0910GD with similar models in the same series. See all 120 models on the Schneider Contactors TeSys K Contactors page.
| Model | [Uc] control circuit voltage | Minimum switching voltage | Hold-in power consumption in VA | Hold-in power consumption in W |
|---|---|---|---|---|
| LP1K0910GD (this model) | 125 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K09015UD | 250 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K09103BD | 24 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K09105BD | 24 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K0910ED | 48 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K0910SD | 72 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K12004BD | 24 V DC | - | - | 3 W at 20 °C |
| LP4K0610FW3 | 110 V DC | 17 V for signalling circuit | - | 1.8 W at 20 °C |
| LP4K09004BW3 | 24 V DC | - | - | 1.8 W at 20 °C |