
Image for reference. Refer to the datasheet for exact dimensions.
LR2D3559: Schneider Electric Overload Relay For Motor Protection
Schneider LR2D3559, Overload Relay For Motor Protection. Ensure motor safety—ask IndMALL for pricing today and optimize your motor control systems.
- Brand
- Schneider
- Model number
- LR2D3559
- Series
- Schneider Contactors TeSys Deca Overload Relay
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider LR2D3559 technical specifications
| Device short name | LR2D |
|---|---|
| Range | TeSys |
| Product name | TeSys LRDTeSys Deca |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Height | 100 mm |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Temperature compensation | -20…60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Thermal overload class | Class 20 conforming to IEC 60947-4-1 |
| Network type | DCAC |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Control type | Red push-button: stopBlue push-button: reset |
| Mechanical robustness | Vibrations: 6 Gn conforming to IEC 60068-2-6Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 |
| [Ue] rated operational voltage | 1000 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit4 A BS for signalling circuit |
| Product certifications | IECULCSAEACDNV-GLLROS (Lloyds register of shipping)UKCA |
| Permissible current | 0.72 A at 500 V AC-15 for signalling circuit0.06 A at 440 V DC-13 for signalling circuit |
| Depth | 121 mm |
| Width | 75 mm |
| Ambient air temperature for storage | -60…70 °C |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Dielectric strength | 2.2 kV at 50 Hz conforming to IEC 60947-1 |
| Thermal protection adjustment range | 48…65 A |
| Flame retardance | V1 conforming to UL 94 |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminalsPower circuit: 9 N.m - on screw clamp terminals |
| Mounting support | Plate, with specific accessoriesRail, with specific accessoriesUnder contactor |
| Relay application | Motor protection |
| Net weight | 0.535 kg |
Overview
Technical Specifications of Schneider Electric Overload Relay For Motor Protection LR2D3559: Talk to Our Engineer for Schneider Electric Overload Relay For Motor Protection LR2D3559 with exclusive offers. Core System Specifications of LR2D3559 are device short name LR2D, from the TeSys range. It has a conventional free air thermal current [Ith] of 5 A for signalling circuit, making it suitable for demanding environments. With a height of 100 mm and an IP20 conforming to IEC 60529, it provides protection against solid objects. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C, with temperature compensation to maintain performance. The control type consists of a Red push-button: stopBlue push-button: reset.
Datasheet
Schneider datasheetschneider-electric-lr2d3559.pdfOther models in this series
Compare LR2D3559 with similar models in the same series. See all 107 models on the Schneider Contactors TeSys Deca Overload Relay page.
| Model | Range | Thermal protection adjustment range | [Uimp] rated impulse withstand voltage | Network type |
|---|---|---|---|---|
| LR2D3559 (this model) | TeSys | 48…65 A | 6 kV | DCAC |
| LRD16L | TeSysTeSys Deca | 9…13 A | 6 kV | DCAC |
| LRD12L | TeSysTeSys Deca | 5.5…8 A | 6 kV | ACDC |
| LRD22L | TeSysTeSys Deca | 17…24 A | 6 kV | ACDC |
| LRD313 | TeSysTeSys Deca | 9…13 A | 6 kV | ACDC |
| LRD086 | TeSysTeSys Deca | 2.5…4 A | 6 kV | DCAC |
| LRD126 | TeSysTeSys Deca | 5.5…8 A | 6 kV | DCAC |
| LRD1522 | TeSys | 17…25 A | 6 kV | ACDC |
| LRD365L | TeSysTeSys Deca | 48…65 A | 6 kV | DCAC |