Image for reference. Refer to the datasheet for exact dimensions.
Wenglor WP02PAT80 Color Sensor
Give Us a Call for Wenglor RS-232 Interface Color Sensor WP02PAT80 at economical prices. 400 ... 700 nm, 10,000 Lux, 0.7 × 2 mm, 10 ... 30 V DC, < 50 mA.
- Brand
- Wenglor
- Model number
- WP02PAT80
- Series
- Wenglor Laser Contrast Sensor
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Wenglor WP02PAT80 technical specifications
| Working Range | 12 ... 16 mm |
|---|---|
| Working Distance | 14 mm |
| Resolution (Gray Scale) | 100 |
| Switching Hysteresis | < 1 % |
| Light Source | White Light |
| Wavelength | 400 ... 700 nm |
| Max. Ambient Light | 10,000 Lux |
| Light Spot Diameter | 0.7 × 2 mm |
| Supply Voltage | 10 ... 30 V DC |
| Current Consumption (Ub = 24 V) | < 50 mA |
| Switching Frequency | 25 kHz |
| Response Time | 20 µs |
| Temperature Range | -25 ... 60 °C |
| Switching Output Voltage Drop | 1,5 V |
| Switching Output/Switching Current | 200 mA |
| Setting Method | Teach-In |
| Housing Material | Plastic, ABS, Plastic, PC |
| Optic Cover | Plastic, PMMA |
| Degree of Protection | IP67 |
| Connection | M12 × 1; 8-pin |
| Output | NPN NC, NPN NO; RS-232 Interface |
| Weight | 40 g |
Overview
The Wenglor WP02PAT80 Color Sensor offers 12 ... 30 V DC supply voltage, 100, 25 kHz, NPN NC, NPN NO; RS-232 Interface output. 16 mm it provides a working distance of 14 mm and a high resolution of 100 gray scales. It can handle ambient light up to 10,000 Lux and features a light spot diameter of 0.7 × 2 mm. 30 V DC, consuming < 50 mA, with a switching frequency of 25 kHz and a response time of 20 µs. The device is equipped with a Teach-In setting method, housed in durable Plastic, ABS, Plastic, PC with a Plastic, PMMA optic cover, and offers IP67 protection.
Datasheet
Wenglor datasheetwp02pat80.pdfOther models in this series
Compare WP02PAT80 with similar models in the same series. See all 17 models on the Wenglor Laser Contrast Sensor page.
| Model | Setting Method | Temperature Range | Working Distance | Working Range |
|---|---|---|---|---|
| WP02PAT80 (this model) | Teach-In | -25 ... 60 °C | 14 mm | 12 ... 16 mm |
| YP11VAH3ABF | Potentiometer | -10 ... 60 °C | 100 mm | 60 ... 100 mm |
| YP11MVV80 | Potentiometer | -10 ... 60 °C | 50 mm | 50 ... 100 mm |
| P1PW001 | Teach-In | -25 ... 60 °C | 35 mm | 30 ... 40 mm |
| WM03NCT2 | Teach-In | -25 ... 60 °C | 15 mm | 12 ... 18 mm |
| WM03PCT2 | Teach-In | -25 ... 60 °C | 15 mm | 12 ... 18 mm |
| WP04NAT80 | Teach-In | -25 ... 60 °C | 35 mm | 30 ... 40 mm |
| WP04PAT80 | Teach-In | -25 ... 60 °C | 35 mm | 30 ... 40 mm |
| OFP401P0189 | Menu (OLED) | -25 ... 60 °C | 35 mm | 30 ... 40 mm |