Image for reference. Refer to the datasheet for exact dimensions.
Delta DVP04TC-S Programmable Logic Controller
Delta DVP04TC-S Programmable Logic Controller (PLC) from the DVP-S Series offers 4-channel J/K/R/S/T thermocouple input with 0.1°C resolution and RS-485 interface.
- Brand
- Delta
- Model number
- DVP04TC-S
- Series
- DVP-S Series
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Delta DVP04TC-S technical specifications
| Built-in | RS-485 interface |
|---|---|
| Power Supply Voltage | 24VDC (-15%~20%) |
| Resolution | 0.1 °C |
| Analog I/O Modules | 4 points of thermocouple (J, K, R, S, T type) sensor input* |
| Fuse capacity | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC |
| Power Consumption | 2W |
| Spike Voltage Durability | 1500VAC (Primary-secondary); 1500VAC (Primary-PE); 500VAC (Secondary-PE) |
| Insulation Impedance | >5 MΩ (all I/O point-to-ground: 500VDC) |
| Noise Immunity | ESD: 8 kV Air Discharge EFT: Power Line, 2 kV Digital I/O: 1 kV Analog & Communication I/O: 1 kV RS: 26 MHz~1GHz, 10V/m |
| Earth | The diameter of grounding wire shall not be shorter than that of the power supply cable. (When many PLCs are in use at the same time, please make sure every PLC is properly grounded.) |
| Storagr Operation Temperature | Storage: -25ºC ~70ºC (temperature) Operation: 0ºC ~55ºC (temperature) |
| Storage Operation Humidity | Storage: -25ºC ~70ºC (temperature) Operation: 0ºC ~55ºC (temperature) |
| Response Time | 3ms |
| Input Signal Voltage | 24VDC ±10% (5 mA) |
Overview
Delta DVP04TC-S Programmable Logic Controller (PLC) is a precise Temperature Measurement Module designed for accurate thermocouple-based monitoring in industrial applications. It supports 4 thermocouple input channels for types J, K, R, S, and T , offering a high-resolution 0.1°C measurement accuracy ideal for heating, melting, packaging, and thermal process control. It comes with strong electrical protection including fuse capacities of ES: 2A/250VAC and SV: 2.5A/30VDC, spike voltage durability up to 1500VAC, and insulation impedance greater than 5 MΩ. With a fast 3 ms response time, IP-rated noise immunity, and robust grounding recommendations, the Delta DVP04TC-S2 is built to handle industrial electrical conditions while delivering accurate data to control systems.
Datasheet
Delta datasheetdvp-series.pdfOther models in this series
Compare DVP04TC-S with similar models in the same series. See all 205 models on the DVP-S Series page.
| Model | Number of Outputs and Type | Fuse Capacity | Power consumption | Program capacity |
|---|---|---|---|---|
| DVP04TC-S (this model) | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2W | — |
| DVP04AD-SL | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 3.5W | — |
| DVP202LC-SL | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 5 W | — |
| DVP06PT-S | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2W | — |
| DVP04PT-S | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2W | — |
| DVP02TUN-S | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2.4 W maximum | — |
| DVP02TUR-S | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2.4 W | — |
| DVP02TUL-S | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2.4 W | — |
| DVP06SN11R | 6- Relay | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 1.5W | 16k Steps |