Image for reference. Refer to the datasheet for exact dimensions.
Delta DVP06PT-S PLC Temperature Measurement Module
Delta DVP06PT-S PLC temperature Module from the DVP-S Series supports 6-point RTD input with 0.1°C resolution for industrial monitoring.
- Brand
- Delta
- Model number
- DVP06PT-S
- Series
- DVP-S Series
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Delta DVP06PT-S technical specifications
| Power Supply Voltage | 24VDC (-15%~20%) |
|---|---|
| Resolution | 0.1 °C |
| Analog I/O Modules | 6 points of platinum RTD (Pt100, Pt1000, Ni100, Ni1000) sensor input |
| Fuse capacity | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC |
| Power Consumption | 2W |
| Spike Voltage Durability | 1500VAC (Primary-secondary); 1500VAC (Primary-PE); 500VAC (Secondary-PE) |
| Insulation Impedance | >5 MΩ (all I/O point-to-ground: 500VDC) |
| Noise Immunity | ESD: 8 kV Air Discharge EFT: Power Line, 2 kV Digital I/O: 1 kV Analog & Communication I/O: 1 kV RS: 26 MHz~1GHz, 10V/m |
| Earth | The diameter of grounding wire shall not be shorter than that of the power supply cable. (When many PLCs are in use at the same time, please make sure every PLC is properly grounded.) |
| Storagr Operation Temperature | Storage: -25ºC ~70ºC (temperature) Operation: 0ºC ~55ºC (temperature) |
| Storage Operation Humidity | Storage: -25ºC ~70ºC (temperature) Operation: 0ºC ~55ºC (temperature) |
| Response Time | 200ms |
| Input Signal Voltage | 24VDC ±10% (5 mA) |
Overview
Delta DVP06PT-S Programmable Logic Controller (PLC) is a temperature measurement Module designed for high-accuracy industrial sensing applications. It supports 6 points of platinum RTD input including Pt100, Pt1000, Ni100, and Ni1000 , delivering precise monitoring with a 0.1°C resolution . Operating on a stable 24 VDC power supply , it ensures consistent temperature readings for PLC-controlled processes. From a technical standpoint, the Delta DVP06PT-S offers fast response performance with a 200 ms sampling cycle and low 2 W power consumption . In practical applications, the Delta DVP06PT-S PLC temperature Module is used in process automation, HVAC systems, energy management, food processing lines, chemical plants, and metal treatment equipment.
Datasheet
Delta datasheetdvp-series.pdfOther models in this series
Compare DVP06PT-S with similar models in the same series. See all 205 models on the DVP-S Series page.
| Model | Number of Outputs and Type | Fuse Capacity | Power consumption | Program capacity |
|---|---|---|---|---|
| DVP06PT-S (this model) | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2W | — |
| DVP06AD-S | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2W | — |
| DVP02DA-S | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2W | — |
| DVP04AD-SL | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 3.5W | — |
| DVP202LC-SL | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 5 W | — |
| DVP04PT-S | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2W | — |
| DVP04TC-S | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2W | — |
| DVP02TUN-S | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2.4 W maximum | — |
| DVP02TUR-S | — | ES: 2A/ 250VAC; SV: 2.5A/ 30VDC | 2.4 W | — |