Image for reference. Refer to the datasheet for exact dimensions.
Delta RTU-485 PLC Remote I/O Communication Module
Delta RTU-485 PLC Remote I/O module supports RS-485 communication, Modbus ASCII/RTU protocol, 24VDC supply, and 500VDC isolation.
- Brand
- Delta
- Model number
- RTU-485
- Series
- DVP-S Series
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Delta RTU-485 technical specifications
| Power Supply Voltage | 24 VDC (-15 to 20%) |
|---|---|
| Storage /Operation Temperature | Storage: -25ºC ~70ºC (temperature)Operation: 0ºC ~55ºC (temperature) |
| Storage /Operation humidity | 5%~95% (humidity)5%~95% (humidity); pollution degree 2 |
| Vibration/shock immunity | Standard: IEC 61131-2、IEC 68-2-6 (TEST Fc)/IEC 61131-2 & IEC 68-2-27(TEST Ea) |
| Transmission method | RS-485 |
| Connector | 3-pin, removable |
| Serial baudrate | 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps |
| Data type | Modbus ASCII/RTU |
| Electrical isolation | 500 VDC |
| Transmission cable | 2-wire twister shielded cablew8 |
| Noise immunity | ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge,4KV ContactDischargeEFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2KV, Digital I/O: 1KVAnalog & Communication I/O: 1KVDamped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KVRS (IEC 61131-2, IEC 61000-4-3): 80MHz~1000MHz , 1.4GHz~2.0GHz ,10V/m |
Overview
Delta RTU-485 Programmable Logic Controller (PLC) is a remote I/O communication module designed for RS-485 based expansion in PLC systems. It supports Delta PLC 485 Communication using Modbus ASCII/RTU , operates on a 24 VDC power supply , and provides 500 VDC electrical isolation for stable field connectivity. It enables RS-485 serial communication with Modbus ASCII and RTU protocols, supporting baud rates from 1,200 to 115,200 bps . In practical applications, the Delta RTU-485 is used to extend digital and analog I/O over long distances in factories, utilities, and process automation setups. The module is commonly deployed in conveyors, pumping stations, material handling systems, and distributed control panels.
Datasheet
Delta datasheetdvp-series.pdfOther models in this series
Compare RTU-485 with similar models in the same series. See all 205 models on the DVP-S Series page.
| Model | Number of Outputs and Type | Fuse Capacity | Power consumption | Program capacity |
|---|---|---|---|---|
| RTU-485 (this model) | Transmission method: RS-485 · Connector: 3-pin, removable · Data type: Modbus ASCII/RTU | |||
| DVP20SX211T | Analog (2), Relay (6) | 2A/ 250VAC; SV: 2.5A/ 30VDC | 4W | 16k Steps |
| DVP20PM00D | — | 2A/ 250VAC | 60 VA | 64K Steps |
| DVP20PM00M | — | 2A/ 250VAC | 60 VA | 64K Steps |
| DVP10PM00M | 16 | 2A/ 250VAC | 60VA | 64k steps |
| DVP20PM00DT | 8 | 2A/ 250VAC | 60 VA | 64k steps |
| DVP10MC11T | 4 Outputs | 3 A/30 VDC, Polyswitch | 8 W Max | Ladder 16k steps / Motion 1Mbyte |
| RTU-DNET | Transmission method: CAN · Connector: Removable, 5.08mm · Message type: Explicit, I/O polled | |||
| RTU-EN01 | — | — | 2 W | — |