Image for reference. Refer to the datasheet for exact dimensions.
Multispan PM-133-E3-06: Digital AVF Meters
PM-133-E3-06 from Multispan Digital AVF Meters. IndMALL is ready—start a chat today!
- Brand
- Multispan
- Model number
- PM-133-E3-06
- Series
- Multispan Digital AVF Meter
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Multispan PM-133-E3-06 technical specifications
| Direct Voltage AC | 50 to 300V (L - N)87 to 519V (L - L) |
|---|---|
| Burden (Voltage) | < 0.2 VA |
| Primary CT Ratio | 5 to 3000 Selectable |
| Secondary Current AC | 5 Amp |
| Burden (Current) | < 0.2 VA |
| Overload | Upto 6A Continuous |
| Frequency | 45.0 to 65.0 Hz |
| Voltage | VLL, VLN, Avg |
| Current | CT Input: 60A with DIN 60AX CT |
| Frequency (Calculated) | System Frequency |
| Load Hour | Upto 9999Hr, 59 Min |
| Power Factor | L1, L2, L3, Avg |
| kilo Watt | L1, L2, L3, Total |
| RPM | 2 to 100 Pole |
| Power Supply | 100 to 270V AC/DC, 50/60Hz |
| Burden (Power) | 4VA |
| Display | 3-Digit, 6-Line, 7-Seg White Display 0.36” LED |
| Key | Set, PF/W, Inc, Dec |
| LED Indication | A, KA, VLL, VLN, PF, Hz, Kw |
| Working Temperature | 0 to 55°C |
| Storage Temperature | 0 to 55°C |
| Relative Humidity | 95% RH Non-Condensing |
| Protection Level | IP-65 (Front side As per IS/IEC 60529 : 2001) |
| Size (mm) | 96 (H) x 96 (W) x 54 (D) |
| Panel Cutout (mm) | 92 (H) x 92 (W) |
Overview
Technical Specifications of Multispan Digital AVF Meters PM-133-E3-06:
Datasheet
Multispan datasheetpm-133.pdfOther models in this series
Compare PM-133-E3-06 with similar models in the same series. See all 12 models on the Multispan Digital AVF Meter page.
| Model | Direct Voltage AC | Power Supply | Voltage | Burden (Power) |
|---|---|---|---|---|
| PM-133-E3-06 (this model) | 50 to 300V (L - N)87 to 519V (L - L) | 100 to 270V AC/DC, 50/60Hz | VLL, VLN, Avg | 4VA |
| AVF-19D-B1-N6 | 30 to 300V (L - N); 50 to 520V (L - L) | 230V AC, 50Hz ± 20% | VLL, VLN, Avg | 3VA |
| AVF-19D-B1-N8 | 30 to 300V (L - N); 50 to 520V (L - L) | 230V AC, 50Hz ± 20% | VLL, VLN, Avg | 3VA |
| AVF-29T-E3-00 | 30 to 300V (L - N); 50 to 520V (L - L) | 100 to 270V AC, 50/60Hz | VLL, VLN, Avg. | 4VA |
| AVF-29T-E3-06 | 30 to 300V (L - N); 50 to 520V (L - L) | 100 to 270V AC, 50/60Hz | VLL, VLN, Avg. | 4VA |
| AVF-29T-E3-07 | 30 to 300V (L - N); 50 to 520V (L - L) | 100 to 270V AC, 50/60Hz | VLL, VLN, Avg. | 4VA |
| AVF-29T-E3-08 | 30 to 300V (L - N); 50 to 520V (L - L) | 100 to 270V AC, 50/60Hz | VLL, VLN, Avg. | 4VA |
| AVF-19T-E3-N0 | 30 to 300V (L - N) 50 to 520V (L - L) | 100 to 270V AC/DC,50/60Hz | VLL, VLN, Avg. | 4VA |
| PM-133-E3-00 | 50 to 300V (L - N)87 to 519V (L - L) | 100 to 270V AC/DC, 50/60Hz | VLL, VLN, Avg | 4VA |