Image for reference. Refer to the datasheet for exact dimensions.
Omron H7CC-R11D Counter
Omron H7CC-R11D Counter offers high-speed tachometer accuracy with 10 kHz input, SPDT output, dual inputs, and a clear 6-digit LCD for industrial monitoring.
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Omron H7CC-R11D technical specifications
| Power consumption | 5.5 VA/3.3 W |
|---|---|
| External power supply | 12 VDC (±10%), 100 mA * Refer to Safety Precautions (Common) on page 61 for details. |
| Max. counting speed | 30 Hz (minimum pulse width: 16.7 ms) 10 kHz (minimum pulse width: 0.05 ms) |
| Counter Input mode | No-voltage Input Impedance when ON: 1 kΩ max. (Leakage current: 12 mA when 0 Ω) ON residual voltage: 3 V max. Impedance when OFF: 100 kΩ min. Voltage Input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ) |
| Counter One-shot output time | 0.001 to 99.999 (in Tachometer Mode)/ 0.0 to 99.9 s |
| Input signal | Count and hold |
| Prescaling function | 0.001 to 99.999 (in Tachometer Mode) |
| Classification | Tachometer |
| Configuration | Tachometer |
| Power supply voltage | 24 VAC/ 12 to 48 VDC |
| Mounting method | Flush mounting or surface mounting |
| External connections | 11-pin socket |
| Outputs | Contact output (SPDT) |
| Digits | 6 digits (0 to 999999) |
| Operating voltage fluctuation range | 85% to 110% of rated supply voltage (12 to 48 VDC: 90% to 110%) |
| Sensor waiting time | 290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) |
| Counter Reset system | 290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) |
| Tachometer | Rightmost 3 digits |
| Control output | Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1) Minimum applied load:10 mA at 5 VDC (failure level: P, reference value) |
| Display | 7-segment, negative transmissive LCD Character height Present value: 10 mm (white), comparison value: 6 mm (green) |
| Memory backup | Non-volatile memory (overwrites: 100,000 times min.) that can store data for 10 years min |
| Storage temperature range | −10 to 55°C (−10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation) |
| Operating humidity range | 25% to 85% |
| Input mode | No-voltage (NPN) input/voltage (PNP) input (switchable) No-voltage inputs: ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min. Voltage input: High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ) |
| Degree of protection | IEC IP66 for panel surface only and only when Y92S-P6 Waterproof Packing is used |
| Case color | Black (N1.5) |
Overview
The Omron H7CC-R11D Counter is a precision tachometer engineered for high-speed rotational and frequency measurement in industrial systems. It supports dual input channels with count-and-hold functionality, a fast 10 kHz maximum counting speed, and SPDT contact outputs for reliable control. The clear 6-digit LCD display enhances visibility, while IP66 panel protection ensures durability in demanding environments. With flexible NPN/PNP input compatibility and stable 24 VAC/12–48 VDC operation, it fits a wide range of machine monitoring requirements. Manufactured by Omron and listed under Omron Counter solutions, it belongs to the Omron H7CC Series .
Datasheet
Omron datasheeth7cc-series.pdfOther models in this series
Compare H7CC-R11D with similar models in the same series. See all 20 models on the H7CC Series page.
| Model | Mounting method | External connections | Input signal | Classification |
|---|---|---|---|---|
| H7CC-R11D (this model) | Flush mounting or surface mounting | 11-pin socket | Count and hold | Tachometer |
| H7CC-AUD | Flush mounting | Screw terminals | CP1, CP2, reset 1, and reset 2 | Preset counter/ Tachometer |
| H7CC-A11D | Flush mounting or surface mounting | 11-pin socket | CP1, CP2, reset, and total reset | Preset counter |
| H7CC-AWD | Flush mounting | Screw terminals | CP1, CP2, reset 1, and reset 2 | Preset counter/ Tachometer |
| H7CC-AWS | Flush mounting | Screw terminals | CP1, CP2, reset 1, and reset 2 | Preset counter/ Tachometer |
| H7CC-AWSD | Flush mounting | Screw terminals | CP1, CP2, reset 1, and reset 2 | Preset counter/ Tachometer |
| H7CC-R | Flush mounting or surface mounting | 11-pin socket | Count and hold | Tachometer |
| H7CC-R11 | Flush mounting or surface mounting | 11-pin socket | Count and hold | Tachometer |
| H7CC-R11W | Flush mounting or surface mounting | 11-pin socket | CP1, CP2, reset 1, and reset 2 | Tachometer |