Schneider Contactors Acti9 iC60
Schneider Contactors Acti9 iC60 products are designed for reliable switching, protection, and control in electrical distribution applications. The Acti9 range supports efficient circuit management in commercial and industrial installations.
- 71models
- AC / ACDC / DCACnetwork type
- 85 mm / 91 mmheight

Models in this series
Open a model for full specifications, or enquire directly.
Showing all 71 models
| Image | Model | [In] rated current | Network type | Height | Magnetic tripping limit | Enquiry |
|---|---|---|---|---|---|---|
![]() |
A9F04106 | 6 A | ACDC | 91 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F04206 | 6 A | ACDC | 91 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F74201 | 1 A | ACDC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F74216 | 16 A | ACDC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F85216 | 16 A | DCAC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F85416 | 16 A | DCAC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F89310 | 10 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F89316 | 16 A | ACDC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F90210 | 10 A | AC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F90282 | 12.5 A | AC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F92104 | 4 A | DCAC | 85 mm | 3 x In +/- 20 % | Enquire |
![]() |
A9F92110 | 10 A | DCAC | 85 mm | 3 x In +/- 20 % | Enquire |
![]() |
A9F92120 | 20 A | ACDC | 85 mm | 3 x In +/- 20 % | Enquire |
![]() |
A9F92204 | 4 A | ACDC | 85 mm | 3 x In +/- 20 % | Enquire |
![]() |
A9F92206 | 6 A | ACDC | 85 mm | 3 x In +/- 20 % | Enquire |
![]() |
A9F92210 | 10 A | DCAC | 85 mm | 3 x In +/- 20 % | Enquire |
![]() |
A9F92325 | 25 A | ACDC | 85 mm | 3 x In +/- 20 % | Enquire |
![]() |
A9F92332 | 32 A | ACDC | 85 mm | 3 x In +/- 20 % | Enquire |
![]() |
A9F92350 | 50 A | ACDC | 85 mm | 3 x In +/- 20 % | Enquire |
![]() |
A9F92363 | 63 A | DCAC | 85 mm | 3 x In +/- 20 % | Enquire |
![]() |
A9F92404 | 4 A | ACDC | 85 mm | 3 x In +/- 20 % | Enquire |
![]() |
A9F93132 | 32 A | DCAC | 85 mm | 4 x In +/- 20 % | Enquire |
![]() |
A9F93170 | 0.5 A | ACDC | 85 mm | 4 x In +/- 20 % | Enquire |
![]() |
A9F93206 | 6 A | ACDC | 85 mm | 4 x In +/- 20 % | Enquire |
![]() |
A9F93216 | 16 A | DCAC | 85 mm | 4 x In +/- 20 % | Enquire |
![]() |
A9F93232 | 32 A | ACDC | 85 mm | 4 x In +/- 20 % | Enquire |
![]() |
A9F93263 | 63 A | ACDC | 85 mm | 4 x In +/- 20 % | Enquire |
![]() |
A9F93332 | 32 A | DCAC | 85 mm | 4 x In +/- 20 % | Enquire |
![]() |
A9F93363 | 63 A | DCAC | 85 mm | 4 x In +/- 20 % | Enquire |
![]() |
A9F93410 | 10 A | DCAC | 85 mm | 4 x In +/- 20 % | Enquire |
![]() |
A9F93416 | 16 A | DCAC | 85 mm | 4 x In +/- 20 % | Enquire |
![]() |
A9F94101 | 1 A | ACDC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94104 | 4 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94116 | 16 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94202 | 2 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94203 | 3 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94216 | 16 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94225 | 25 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94232 | 32 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94240 | 40 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94270 | 0.5 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94304 | 4 A | ACDC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94306 | 6 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94310 | 10 A | ACDC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94320 | 20 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94325 | 25 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94340 | 40 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94350 | 50 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94402 | 2 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94406 | 6 A | ACDC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94410 | 10 A | ACDC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94416 | 16 A | ACDC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94420 | 20 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94432 | 32 A | DCAC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F94463 | 63 A | ACDC | 85 mm | 8 x In +/- 20 % | Enquire |
![]() |
A9F95106 | 6 A | DCAC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F95110 | 10 A | ACDC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F95125 | 25 A | ACDC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F95132 | 32 A | ACDC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F95204 | 4 A | ACDC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F95216 | 16 A | DCAC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F95220 | 20 A | ACDC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F95225 | 25 A | DCAC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F95310 | 10 A | DCAC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F95320 | 20 A | ACDC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F95332 | 32 A | ACDC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F95340 | 40 A | DCAC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F95402 | 2 A | DCAC | 85 mm | 12 x In +/- 20 % | Enquire |
![]() |
A9F93140 | 40 A | ACDC | 85 mm | 4 x In +/- 20 % | Enquire |
![]() |
A9F93150 | 50 A | DCAC | 85 mm | 4 x In +/- 20 % | Enquire |
![]() |
A9F95140 | 40 A | DCAC | 85 mm | 12 x In +/- 20 % | Enquire |
All listed models: Range: Acti9; Product or component type: Miniature circuit-breaker; Network frequency: 50/60 Hz; Contact position indicator: Yes; Control type: Toggle; Local signalling: Trip indicator. Specifications are taken from each model's product page. Confirm details on each model page or in the manufacturer's datasheet before ordering.
Not sure which model you need?