Image for reference. Refer to the datasheet for exact dimensions.
A9F93332: Schneider iC60L 3P 32A B Curve
Schneider A9F93332, iC60L 3P 32A B Curve. Ensure performance—request a quote from IndMALL today for high-efficiency circuit breaker solutions.
- Brand
- Schneider
- Model number
- A9F93332
- Series
- Schneider Contactors Acti9 iC60
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider A9F93332 technical specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product or component type | Miniature circuit-breaker |
| Device short name | iC60L |
| Poles description | 3P |
| Number of protected poles | 3 |
| [In] rated current | 32 A |
| Network type | DCAC |
| Trip unit technology | Thermal-magnetic |
| Network frequency | 50/60 Hz |
| Magnetic tripping limit | 4 x In +/- 20 % |
| Limitation class | 3 conforming to EN 60898-13 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-26 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| Local signalling | Trip indicator |
| Mounting support | DIN rail |
| Height | 85 mm |
| Width | 54 mm |
| Depth | 78.5 mm |
| Net weight | 0.375 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 3.5 N.m top or bottom |
| IP degree of protection | IP20 conforming to IEC 60529IP20 conforming to EN 60529 |
| Relative humidity | 95 % at 55 °C |
| Ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
Overview
Technical Specifications of Schneider iC60L 3P 32A B Curve A9F93332: Call us for Schneider iC60L 3P 32A B Curve A9F93332 at the best rates. Technical Attributes of A9F93332 are Acti9 range and provides a rated current of 32 A. With compact dimensions, it features a height of 85 mm, a width of 54 mm, and a depth of 78.5 mm, allowing it to fit seamlessly into space-constrained control panels. Get in touch for a quote on the Acti9 iC60 circuit breaker. Unlock Exclusive Pricing with a Quote for your requirement of Schneider iC60L 3P 32A B Curve.
Datasheet
Schneider datasheetschneider-electric-a9f93332.pdfOther models in this series
Compare A9F93332 with similar models in the same series. See all 71 models on the Schneider Contactors Acti9 iC60 page.
| Model | [In] rated current | Network type | Height | Magnetic tripping limit |
|---|---|---|---|---|
| A9F93332 (this model) | 32 A | DCAC | 85 mm | 4 x In +/- 20 % |
| A9F93206 | 6 A | ACDC | 85 mm | 4 x In +/- 20 % |
| A9F93216 | 16 A | DCAC | 85 mm | 4 x In +/- 20 % |
| A9F93232 | 32 A | ACDC | 85 mm | 4 x In +/- 20 % |
| A9F93263 | 63 A | ACDC | 85 mm | 4 x In +/- 20 % |
| A9F93363 | 63 A | DCAC | 85 mm | 4 x In +/- 20 % |
| A9F93410 | 10 A | DCAC | 85 mm | 4 x In +/- 20 % |
| A9F93416 | 16 A | DCAC | 85 mm | 4 x In +/- 20 % |
| A9F94101 | 1 A | ACDC | 85 mm | 8 x In +/- 20 % |