Image for reference. Refer to the datasheet for exact dimensions.
ATS480C14Y - Schneider Altistart 480 140A Soft Starter
Schneider ATS480C14Y, Altistart 480 140A Soft Starter. ⏩ Best deals , premium stock ✅, and express delivery at IndMALL!
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider ATS480C14Y technical specifications
| Range of Product | Altivar Soft Starter ATS480 |
|---|---|
| Motor power kW | 37.0 kW at 230 V in the motor supply line normal duty30.0 kW at 230 V in the motor supply line heavy duty75.0 kW at 400 V in the motor supply line normal duty55.0 kW at 400 V in the motor supply line heavy duty75.0 kW at 440 V in the motor supply line normal duty55.0 kW at 440 V in the motor supply line heavy duty90.0 kW at 500 V in the motor supply line normal duty75.0 kW at 500 V in the motor supply line heavy duty90.0 kW at 525 V in the motor supply line normal duty75.0 kW at 525 V in the motor supply line heavy duty110.0 kW at 660 V in the motor supply line normal duty90.0 kW at 660 V in the motor supply line heavy duty110.0 kW at 690 V in the motor supply line normal duty90.0 kW at 690 V in the motor supply line heavy duty75.0 kW at 230 V to the motor delta terminals normal duty55.0 kW at 230 V to the motor delta terminals heavy duty110.0 kW at 400 V to the motor delta terminals normal duty90.0 kW at 400 V to the motor delta terminals heavy duty |
| Rated operational current [Ie] | Normal duty: 140.0 A (at <40 °C) |
| Torque control | TRUE |
| Rated insulation voltage [Ui] | 690 V |
| Minimum switching current | 100 mA at 12 V DC for relay outputs |
| Maximum switching current | Relay outputs 2 A at 250 V ACRelay outputs 2 A at 30 V DCRelay outputs |
| Power supply frequency | 50...60 Hz - 20...20 % |
| Method of access | Slave Modbus serial |
| Package weight | 14.386 kg |
| Discrete Output Type | (DQ1) programmable digital output <= 30 V (DQ2) programmable digital output <= 30 V |
| Analog Output Number | 1 |
| Maximum acceleration under vibratory load (during storage) | 15 m/s² at 200...500 Hz10 m/s² at 9...200 Hz |
| Device Short name | ATS480 |
| Net Weight | 12.4 kg |
| IP Degree protection | IP00 |
| Output Compatibility | Open collector level 1 PLC conforming to IEC 65A-68 |
| [Uc] control circuit voltage | 24 V DC |
| Relay output number | 3 |
| Discrete input logic | Programmable digital input at State 0: < 5 V |
| Communication port protocol | Modbus serial |
| Motor Power Hp | 40.0 hp at 208 V normal duty30.0 hp at 208 V heavy duty50.0 hp at 230 V normal duty40.0 hp at 230 V heavy duty100.0 hp at 460 V normal duty75.0 hp at 460 V heavy duty125.0 hp at 575 V normal duty100.0 hp at 575 V heavy duty |
| Relay Output Type | Relay outputs R1A 1 NORelay outputs R1B 1 NORelay outputs RIC NO/NC programmable |
| Ambient air temperature for operation | 40…60 °C (with current derating of 2 % per °C)-15…40 °C (without derating) |
| data format | 8 bits, configurable odd, even or no parity |
| Pollution Degree | Level 3 |
| Ambient air temperature for storage | -25…70 °C |
| Relative Humidity | 0…95 % without condensation or dripping water conforming to IEC 60068-2-3 |
| Width | 200.0 mm |
| Ue power supply voltage | 208...690 V - 15...10 % |
| Connection Type | 1 RJ45 |
Overview
ATS480C14Y covers the key specifications of the Schneider ATS480C14Y Soft Starter , an industrial-grade VFD designed to handle motor currents up to 140A . The soft starter is equipped with a 24 V DC control circuit , three relay outputs , two programmable digital outputs (≤30 V), and one analog output for process feedback. Designed for industrial control panels, it features a 200 mm width , 12.4 kg net weight , and operates within -15°C to 60°C at up to 95% humidity. The Schneider Altistart 480 Soft Starter 140A ATS480C14Y is ideal for high-demand applications such as dewatering pumps, crushers, mill drives, compressors, and large conveyors.
Datasheet
Schneider datasheetschneider-electric-ats480c14y.pdfOther models in this series
Compare ATS480C14Y with similar models in the same series. See all 27 models on the ATS480 page.
| Model | Range of Product | Relay output number | Power supply frequency | Ue power supply voltage |
|---|---|---|---|---|
| ATS480C14Y (this model) | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480D62Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480D75Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480D88Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480C11Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480C17Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480C21Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480C25Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480C32Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |