Schneider ATS480C48Y technical specifications

Range of ProductAltivar Soft Starter ATS480
Motor power kW132.0 kW at 230 V in the motor supply line normal duty110.0 kW at 230 V in the motor supply line heavy duty250.0 kW at 400 V in the motor supply line normal duty220.0 kW at 400 V in the motor supply line heavy duty250.0 kW at 440 V in the motor supply line normal duty220.0 kW at 440 V in the motor supply line heavy duty315.0 kW at 500 V in the motor supply line normal duty250.0 kW at 500 V in the motor supply line heavy duty315.0 kW at 525 V in the motor supply line normal duty250.0 kW at 525 V in the motor supply line heavy duty400.0 kW at 660 V in the motor supply line normal duty355.0 kW at 660 V in the motor supply line heavy duty500.0 kW at 690 V in the motor supply line normal duty400.0 kW at 690 V in the motor supply line heavy duty250.0 kW at 230 V to the motor delta terminals normal duty220.0 kW at 230 V to the motor delta terminals heavy duty355.0 kW at 400 V to the motor delta terminals normal duty315.0 kW at 400 V to the motor delta terminals heavy duty
Rated operational current [Ie]Normal duty: 480.0 A (at <40 °C)
Torque controlTRUE
Rated insulation voltage [Ui]690 V
Minimum switching current100 mA at 12 V DC for relay outputs
Maximum switching currentRelay outputs 2 A at 250 V ACRelay outputs 2 A at 30 V DCRelay outputs
Power supply frequency50...60 Hz - 20...20 %
Method of accessSlave Modbus serial
Package weight61.0 kg
Discrete Output Type(DQ1) programmable digital output <= 30 V (DQ2) programmable digital output <= 30 V
Analog Output Number1
Maximum acceleration under vibratory load (during storage)15 m/s² at 200...500 Hz10 m/s² at 9...200 Hz
Device Short nameATS480
Net Weight51.4 kg
IP Degree protectionIP00
Output CompatibilityOpen collector level 1 PLC conforming to IEC 65A-68
[Uc] control circuit voltage24 V DC
Relay output number3
Discrete input logicProgrammable digital input at State 0: < 5 V
Communication port protocolModbus serial
Motor Power Hp150.0 hp at 208 V normal duty125.0 hp at 208 V heavy duty150.0 hp at 230 V heavy duty350.0 hp at 460 V normal duty300.0 hp at 460 V heavy duty400.0 hp at 575 V normal duty350.0 hp at 575 V heavy duty
Relay Output TypeRelay outputs R1A 1 NORelay outputs R1B 1 NORelay outputs RIC NO/NC programmable
Ambient air temperature for operation40…60 °C (with current derating of 2 % per °C)-15…40 °C (without derating)
data format8 bits, configurable odd, even or no parity
Pollution DegreeLevel 3
Ambient air temperature for storage-25…70 °C
Relative Humidity0…95 % without condensation or dripping water conforming to IEC 60068-2-3
Width400.0 mm
Ue power supply voltage208...690 V - 15...10 %
Connection Type1 RJ45
Specifications as listed by IndMALL. Confirm against the manufacturer's datasheet before ordering.

Overview

ATS480C48Y Datasheet outlines all critical details of the Schneider ATS480C48Y Soft Starter , part of the trusted Altistart 480 series . The Schneider ATS480C48Y is built to handle demanding motor control requirements across a wide voltage range, with support for 208–690 V input and rated operational current of 480 A under normal duty at temperatures below 40 °C. The soft starter also includes 3 relay outputs and programmable discrete/analog I/Os for precise control and monitoring. With a robust design that includes IP00 protection and compliance with IEC 60068 environmental standards, the ATS480C48Y maintains consistent performance in temperatures ranging from -25°C to 70°C during storage and -15°C to 60°C during operation.

Datasheet

Schneider datasheetschneider-electric-ats480c48y.pdf

Other models in this series

Compare ATS480C48Y with similar models in the same series. See all 27 models on the ATS480 page.

ATS480C48Y compared with other models in the series
ModelRange of ProductRelay output numberPower supply frequencyUe power supply voltage
ATS480C48Y (this model)Altivar Soft Starter ATS480350...60 Hz - 20...20 %208...690 V - 15...10 %
ATS480C21YAltivar Soft Starter ATS480350...60 Hz - 20...20 %208...690 V - 15...10 %
ATS480C25YAltivar Soft Starter ATS480350...60 Hz - 20...20 %208...690 V - 15...10 %
ATS480C32YAltivar Soft Starter ATS480350...60 Hz - 20...20 %208...690 V - 15...10 %
ATS480C41YAltivar Soft Starter ATS480350...60 Hz - 20...20 %208...690 V - 15...10 %
ATS480C59YAltivar Soft Starter ATS480350...60 Hz - 20...20 %208...690 V - 15...10 %
ATS480C66YAltivar Soft Starter ATS480350...60 Hz - 20...20 %208...690 V - 15...10 %
ATS480C79YAltivar Soft Starter ATS480350...60 Hz - 20...20 %208...690 V - 15...10 %