LP4K09013BW3: Schneider NC 24V DC TeSys K Contactor

Image for reference. Refer to the datasheet for exact dimensions.

LP4K09013BW3: Schneider NC 24V DC TeSys K Contactor

Schneider LP4K09013BW3, NC 24V DC TeSys K Contactor. Ensure efficiency—ask IndMALL for a custom quote today and optimize your control solutions.

Brand
Schneider
Model number
LP4K09013BW3
Series
Schneider Contactors TeSys K Contactors

Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.

Schneider LP4K09013BW3 technical specifications

Connections - terminalsSpring terminals 1 cable(s) 0.75…1.5 mm²solidSpring terminals 1 cable(s) 0.75…1.5 mm²flexible without cable endSpring terminals 2 cable(s) 0.75…1.5 mm²flexible without cable end
[Uc] control circuit voltage24 V DC
Minimum switching voltage17 V for signalling circuit
contactor applicationMotor controlResistive load
Width45 mm
Control circuit typeDC wide range
Average impedance3 mOhm - Ith 16 A 50 Hz for power circuit
Depth57 mm
[Ie] rated operational current9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Auxiliary contacts typetype instantaneous 1 NC
poles description3P
Auxiliary contact composition1 NC
IP degree of protectionIP2X
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Signalling circuit: 600 V conforming to UL 508Power circuit: 600 V conforming to CSA C22.2 No 14Signalling circuit: 600 V conforming to CSA C22.2 No 14
Operating altitude2000 m without derating
Ambient air temperature for operation-25…50 °C
Power pole contact composition3 NO
Hold-in power consumption in W1.8 W at 20 °C
Ambient air temperature for storage-50…80 °C
Utilisation categoryAC-3AC-3eAC-1AC-4
Insulation resistance> 10 MOhm for signalling circuit
Heat dissipation1.8 W
Hold-in power consumption in VA-
Net weight0.235 kg
Minimum switching current5 mA for signalling circuit
Mounting supportRailPlate
Operating time10...20 ms coil de-energisation and NO opening30...40 ms coil energisation and NO closing
Rated breaking capacity110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
Product or component typeContactor
Tightening torque-
Maximum operating rate3600 cyc/h
RangeTeSys
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 HzSignalling circuit: <= 690 V AC <= 400 Hz
Height58 mm
Motor power kW2.2 kW at 220...230 V AC 50/60 Hz AC-34 kW at 380...415 V AC 50/60 Hz AC-34 kW at 440/690 V AC 50/60 Hz AC-32.2 kW at 220...230 V AC 50/60 Hz AC-3e4 kW at 380...415 V AC 50/60 Hz AC-3e4 kW at 440/690 V AC 50/60 Hz AC-3e2.2 kW at 220...230 V AC 50/60 Hz AC-44 kW at 380...415 V AC 50/60 Hz AC-44 kW at 440/690 V AC 50/60 Hz AC-4
Inrush power in W1.8 W (at 20 °C)
[Uimp] rated impulse withstand voltage8 kV
Electrical durability1.3 Mcycles 9 A AC-3 at Ue <= 440 V1.3 Mcycles 9 A AC-3e at Ue <= 440 V0.16 Mcycles 20 A AC-1 at Ue <= 690 V0.02 Mcycles 54 A AC-4 at Ue <= 440 V
Device short nameLP4K
Specifications as listed by IndMALL. Confirm against the manufacturer's datasheet before ordering.

Overview

Technical Specifications of Schneider NC 24V DC TeSys K Contactor LP4K09013BW3: Please speak to our Technical Engineer for Schneider NC 24V DC TeSys K Contactor LP4K09013BW3 at attractive prices. Technical Specs Summary of LP4K09013BW3 includes control circuit voltage [Uc] operates at 24 V DC, with a minimum switching voltage of 17 V for signalling circuit, ensuring responsive operation. The sensor features a 3P design and operates at altitudes up to 2000 m without derating, ensuring versatility across various environments. Heat dissipation 1.3 W, it is energy efficient. Product or component type Contactor. We lead with pricing that's more favorable and support that's more attentive than other Suppliers & Traders.

Datasheet

Schneider datasheetschneider-electric-lp4k09013bw3.pdf

Other models in this series

Compare LP4K09013BW3 with similar models in the same series. See all 120 models on the Schneider Contactors TeSys K Contactors page.

LP4K09013BW3 compared with other models in the series
Model[Uc] control circuit voltageMinimum switching voltageHold-in power consumption in VAHold-in power consumption in W
LP4K09013BW3 (this model)24 V DC17 V for signalling circuit-1.8 W at 20 °C
LP1K09105BD24 V DC17 V for signalling circuit-3 W at 20 °C
LP1K0910ED48 V DC17 V for signalling circuit-3 W at 20 °C
LP1K0910GD125 V DC17 V for signalling circuit-3 W at 20 °C
LP1K0910SD72 V DC17 V for signalling circuit-3 W at 20 °C
LP1K12004BD24 V DC--3 W at 20 °C
LP4K0610FW3110 V DC17 V for signalling circuit-1.8 W at 20 °C
LP4K09004BW324 V DC--1.8 W at 20 °C
LP4K09103BW324 V DC17 V for signalling circuit-1.8 W at 20 °C