Sick RLY3-HAND100 Safety Relay
Give Us a Call for Sick Two Hand Safety Relay RLY3-HAND100, 1085346 with unbeatable choices. Front connector with spring terminals, 24 V DC.
- Brand
- Sick
- Model number
- RLY3-HAND100
- Series
- RLY3 Series
- Product type
- Safety Relay
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Sick RLY3-HAND100 technical specifications
| Compatible sensor types | Two-hand controls Type III C, in accordance with EN ISO 13851 |
|---|---|
| Safety integrity level | SIL 3 (IEC 61508) |
| Category | Category 4 (ISO 13849-1) |
| Performance level | PL e (ISO 13849-1) |
| TM (mission time) | 20 years (ISO 13849-1) |
| Sensor monitoring | - |
| Restart interlock | - |
| Reset | - |
| External device monitoring (EDM) | ✔ |
| Connection type | Front connector with spring terminals |
| Inputs | 4 safety capable inputs for connecting 2 control devices (both with normally closed and normally open), 1 input for external device monitoring (EDM) |
| Outputs | 2 enabling current paths (safe), 1 application diagnostic output (not safe) |
| Display elements | LEDs |
| Configuration method | Hard wired |
| Supply voltage VS | 24 V DC (16.8 V ... 30 V) |
| Residual ripple | ≤ 2.4 V |
| Power consumption | ≤ 2.5 W (DC) |
| Input voltage HIGH | 24 V DC (11 V ... 30 V) |
| Input voltage LOW | 0 V DC (–3 V ... 5 V) |
| Input current | 4 mA ... 6 mA |
| Test pulse width | - |
| Test pulse rate | - |
| Response time | 10 ms |
| Type of output | N/O contacts, positively guided |
| Contact material | Silver alloy, gold flashed |
| Switching voltage | 10 V AC ... 230 V AC, 10 V DC ... 230 V DC |
| Switching current | 10 mA ... 6 A |
| Total current | 12 A |
| Overvoltage category | III (EN 60664-1) |
| Rated impulse withstand voltage Uimp | 6 kV (EN 60664-1) |
| Output voltage HIGH | ≥ Vs – 3 V |
| Output voltage LOW | ≤ 3 V |
| Input current (NPN) | ≤ 15 mA |
| Output current (PNP) | ≤ 120 mA |
| Output voltage | - |
| Test pulse interval | - |
| Dimensions (W x H x D) | 18 mm x 124.6 mm x 85.5 mm |
| Enclosure rating | IP20 (IEC 60529) |
| Ambient operating temperature | –25 °C ... +55 °C |
| Storage temperature | –25 °C ... +70 °C |
| Air humidity | ≤ 95 %, Non-condensing |
| Interference emission | According to IEC 61000-6-4 |
| Interference resistance | According to IEC 61326-3-1, According to IEC 61000-6-2, According to IEC 60947-5-1 |
| Weight | 130 g |
Overview
The RLY3-HAND100 Sick Two Hand Safety Relay is a reliable safety relay designed for two-hand control systems in industrial automation. The positively guided N/O contacts are constructed from silver alloy with gold flashing , supporting switching voltages from 10 V to 230 V (AC/DC) and currents up to 6 A . The RLY3-HAND100 runs on 24 V DC (16.8 V to 30 V) with a ripple of ≤ 2.4 V , consuming ≤ 2.5 W of power. Housed in a compact IP20 enclosure , with dimensions of 18 mm x 124.6 mm x 85.5 mm , it offers space efficiency without compromising performance.
Datasheet
Sick datasheetrly3-hand100-1085346.pdfOther models in this series
Compare RLY3-HAND100 with similar models in the same series. See all 10 models on the RLY3 Series page.
| Model | Configuration method | Input current | Input current (NPN) | Output current (PNP) |
|---|---|---|---|---|
| RLY3-HAND100 (this model) | Hard wired | 4 mA ... 6 mA | ≤ 15 mA | ≤ 120 mA |
| RLY3-EMSS100 | — | |||
| RLY3-TIME100 | Hard wired, DIP switch | 4 mA ... 6 mA | ≤ 15 mA | ≤ 120 mA |
| RLY3-OSSD400 | - | ≤ 60 mA | - | - |
| RLY3-MULT100 | Hard wired, DIP switch | ≤ 60 mA | ≤ 15 mA | ≤ 120 mA |
| RLY3-OSSD100 | - | ≤ 50 mA | - | - |
| RLY3-OSSD200 | — | |||
| RLY3-LOOP100 | Hard wired, DIP switch | 4 mA ... 6 mA | ≤ 15 mA | ≤ 120 mA |
| RLY3-EMSS300 | Hard wired | 4 mA ... 6 mA | ≤ 15 mA | ≤ 120 mA |